[Significance of optic formula selection for postoperative refraction after cataract operation].
Аннотация
BACKGROUND
Prediction of postoperative patient refraction is of paramount importance in modern cataract surgery. The choice of the IOL calculation formula plays a major role here. The influence of popular calculation formulas is evaluated in a prospective study.
MATERIALS AND
METHODS
We performed cataract surgery on 539 eyes with PC-IOL implantation in the capsular bag. The IOL power was computed using 10 different calculation formulas with the help of a personal computer. Patient refraction was examined two days and six months after surgery.
RESULTS
The mean difference between desired and obtained refraction was -0.11 +/- 0.88 dpt 83% of all patients were in a +/- 1 D interval of desired refraction with a median visual acuity of 20/25. The formula used contributes a major part to the precision of calculation despite all problems due to errors of measurement. The theoretical formulas with variable "pseudophacic anterior chamber depth" are superior to the older ones. Standard deviation of the worst formula tested is 25% higher than that of the best one. With the best formula tested there would have been a good result (error < or = 1 D) in 82% of the cases, with the worst one in only 72%.
CONCLUSIONS
The use of older formulas like SRK and Binkhorst should be discontinued and only the newer theoretical formulas (e.g. SRK/T, Holladay, Haigis etc.) be used. This is especially true for short and long eyes. For owners of a personal computer calculation and optimization of those more complex formulas should not be a problem.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.