Influence of intraocular lens haptic material on bacterial isolates from anterior chamber aspirate.
Клиническое исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Agrawal V, Gopinathan U, Singh S, Reddy M, Rao G N
Аннотация
PURPOSE: To determine whether intraocular lens (IOL) type affects the bacterial count in anterior chamber aspirates obtained immediately after cataract surgery.
SETTING: L.V. Prasad Eye Institute, Hyderabad, India.
METHODS: This in vivo study evaluated two groups of eyes that had uneventful cataract extraction and implantation of one of two types of IOLs: all poly(methyl methacrylate) (PMMA) (n = 73) or polypropylene haptic (n = 83). Anterior chamber fluid aspirates (0.1 mL) were obtained with a 30 gauge cannula at the end of surgery and inoculated onto chocolate agar and in thioglycolate broth. Microbiology evaluation was performed using standard methods.
RESULTS: Seven eyes (9.5%) with all-PMMA IOLs and 21 (25.3%) with polypropylene haptic IOLs were positive for bacterial isolates (P = .0322; chi-square test). Mean colony count (+/-SD) was 11.43 +/- 3.78 and 13.16 +/- 4.78 colony-forming units/ milliliter in the PMMA and polypropylene haptic IOL groups, respectively. No eye developed endophthalmitis.
CONCLUSION: Polypropylene haptic IOLs were associated with a significant increase in bacteria in the anterior chamber.
SETTING: L.V. Prasad Eye Institute, Hyderabad, India.
METHODS: This in vivo study evaluated two groups of eyes that had uneventful cataract extraction and implantation of one of two types of IOLs: all poly(methyl methacrylate) (PMMA) (n = 73) or polypropylene haptic (n = 83). Anterior chamber fluid aspirates (0.1 mL) were obtained with a 30 gauge cannula at the end of surgery and inoculated onto chocolate agar and in thioglycolate broth. Microbiology evaluation was performed using standard methods.
RESULTS: Seven eyes (9.5%) with all-PMMA IOLs and 21 (25.3%) with polypropylene haptic IOLs were positive for bacterial isolates (P = .0322; chi-square test). Mean colony count (+/-SD) was 11.43 +/- 3.78 and 13.16 +/- 4.78 colony-forming units/ milliliter in the PMMA and polypropylene haptic IOL groups, respectively. No eye developed endophthalmitis.
CONCLUSION: Polypropylene haptic IOLs were associated with a significant increase in bacteria in the anterior chamber.