DOI 10.1002/mrm.25077

Медицинская библиотека · Magnetic resonance in medicine · 2014

Modeling and correction of bolus dispersion effects in dynamic susceptibility contrast MRI.

Mehndiratta Amit, Calamante Fernando, MacIntosh Bradley J, Crane David E, Payne Stephen J, Chappell Michael A

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: Bolus dispersion in DSC-MRI can lead to errors in cerebral blood flow (CBF) estimation by up to 70% when using singular value decomposition analysis. However, it might be possible to correct for dispersion using two alternative methods: the vascular model (VM) and control point interpolation (CPI). Additionally, these approaches potentially provide a means to quantify the microvascular residue function.

METHODS

VM and CPI were extended to correct for dispersion by means of a vascular transport function. Simulations were performed at multiple dispersion levels and an in vivo analysis was performed on a healthy subject and two patients with carotid atherosclerotic disease.

RESULTS

Simulations showed that methods that could not address dispersion tended to underestimate CBF (ratio in CBF estimation, CBFratio = 0.57-0.77) in the presence of dispersion; whereas modified CPI showed the best performance at low-to-medium dispersion; CBFratio = 0.99 and 0.81, respectively. The in vivo data showed trends in CBF estimation and residue function that were consistent with the predictions from simulations.

CONCLUSION

In patients with atherosclerotic disease the estimated residue function showed considerable differences in the ipsilateral hemisphere. These differences could partly be attributed to dispersive effects arising from the stenosis when dispersion corrected CPI was used. It is thus beneficial to correct for dispersion in perfusion analysis using this method.

Для цитирования: Mehndiratta Amit, Calamante Fernando, MacIntosh Bradley J, Crane David E, Payne Stephen J, Chappell Michael A. Modeling and correction of bolus dispersion effects in dynamic susceptibility contrast MRI.. Magnetic resonance in medicine. 2014. DOI: 10.1002/mrm.25077.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.