MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jmri.24466

Медицинская библиотека · Journal of magnetic resonance imaging : JMRI · 2013

Supra-aortic arteries: three-dimensional time-resolved k-t BLAST contrast-enhanced MRA using a nondedicated body coil at 3 tesla in acute ischemic stroke.

Ferré Jean-Christophe, Raoult Hélène, Breil Stéphane, Carsin-Nicol Béatrice, Ronzière Thomas, Gauvrit Jean-Yves

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To assess the image quality and diagnostic performance achieved by using supra-aortic 3D-TR-CE-k-t BLAST MRA and a nondedicated body coil as compared with conventional CE-MRA in patients with acute ischemic stroke.

MATERIALS AND

METHODS

In this prospective study, 36 consecutive patients with a suspected acute ischemic stroke underwent both k-t BLAST MRA and conventional CE-MRA. Image quality was assessed using visual and quantitative criteria and the techniques were compared. Both techniques were compared for degree of visual and quantitative measurement of carotid stenosis.

RESULTS

Delineation of vessel lumen and overall diagnostic confidence were significantly better with CE-MRA, respectively 3.4 ± 0.5 and 3.3 ± 0.6 (mean score ± SD), than with k-t BLAST MRA, respectively 2.8 ± 0.4 and 2.9 ± 0.5 (P < 0.02). SNR and CNR were significantly higher for k-t BLAST MRA, respectively 33.5 ± 19.3 and 27.9 ± 19.3, than for CE-MRA, respectively 25.7 ± 10 and 20.4 ± 8.4 (P < 0.03). Intertechnique agreement was good for carotid stenosis characterization (κ = .763). For the 14 relevant stenosis, stenosis measurements were highly correlated between techniques (0.96; P < 0.0001). The Bland-Altman plot showed a low bias in assessment of the degree of stenosis (mean bias 2.1% ± 7.7).

CONCLUSION

k-t BLAST MRA using a nondedicated coil offering and dynamic information was a effective diagnostic tool for detection and characterization of carotid stenosis.

Для цитирования: Ferré Jean-Christophe, Raoult Hélène, Breil Stéphane, Carsin-Nicol Béatrice, Ronzière Thomas, Gauvrit Jean-Yves. Supra-aortic arteries: three-dimensional time-resolved k-t BLAST contrast-enhanced MRA using a nondedicated body coil at 3 tesla in acute ischemic stroke.. Journal of magnetic resonance imaging : JMRI. 2013. DOI: 10.1002/jmri.24466.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.