Utility of Whole Slide Imaging for Intraoperative Consultation: Experience of a Large Academic Center.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Shehabeldin Ahmed, Rohra Prih, Sellen Linton D, Zhao Jianping, Alqaidy Doaa, Aramin Hermineh, Hameed Nadia, Perez Ydamis Estrella, Lai Zongshan, Tong Yi Tat, Milton Denái R, Edgerton Mary E, Fuller Gregory, Hansel Donna, Prieto Victor G, Ballester Leomar Y, Aung Phyu P

Аннотация

CONTEXT.—: In the United States, review of digital whole slide images (WSIs) using specific systems is approved for primary diagnosis but has not been implemented for intraoperative consultation.

OBJECTIVE.—: To evaluate the safety of review of WSIs and compare the efficiency of review of WSIs and glass slides (GSs) for intraoperative consultation.

DESIGN.—: Ninety-one cases previously submitted for frozen section evaluation were randomly selected from 8 different anatomic pathology subspecialties. GSs from these cases were scanned on a Leica Aperio AT2 scanner at ×20 magnification (0.25 μm/pixel). The slides were deidentified, and a short relevant clinical history was provided for each slide. Nine board-certified general pathologists who do not routinely establish primary diagnoses using WSIs reviewed the WSIs using Leica Aperio ImageScope viewing software. After a washout period of 2-3 weeks, the pathologists reviewed the corresponding GSs using a light microscope (Olympus BX43). The pathologists recorded the diagnosis and time to reach the diagnosis. Intraobserver concordance, time to diagnosis, and specificity and sensitivity compared to the original diagnosis were evaluated.

RESULTS.—: The rate of intraobserver concordance between GS results and WSI results was 93.7%. Mean time to diagnosis was 1.25 minutes for GSs and 1.76 minutes for WSIs (P < .001). Specificity was 91% for GSs and 90% for WSIs; sensitivity was 92% for GSs and 92% for WSIs.

CONCLUSIONS.—: Time to diagnosis was longer with WSIs than with GSs, and scanning GSs and uploading the data to whole slide imaging systems takes time. However, review of WSIs appears to be a safe alternative to review of GSs. Use of WSIs allows reporting from a remote site during a public health emergency such as the COVID-19 pandemic and facilitates subspecialty histopathology services.