MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12985-023-02167-z

Медицинская библиотека · Virology journal · 2023

Studying temporal titre evolution of commercial SARS-CoV-2 assays reveals significant shortcomings of using BAU standardization for comparison.

Kroidl Inge, Winter Simon, Rubio-Acero Raquel, Bakuli Abhishek, Geldmacher Christof, Eser Tabea M, Déak Flora, Horn Sacha, Zielke Anna, Ahmed Mohamed I M, Diepers Paulina, Guggenbühl Jessica, Frese Jonathan, Bruger Jan, Puchinger Kerstin, Reich Jakob, Falk Philine, Markgraf Alisa, Fensterseifer Heike, Paunovic Ivana, Thomschke Angelika, Pritsch Michael, Riess Friedrich, Saathoff Elmar, Hoelscher Michael, Olbrich Laura, Castelletti Noemi, Wieser Andreas, KoCo19/ORCHESTRA Study Group

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Measuring specific anti-SARS-CoV-2 antibodies has become one of the main epidemiological tools to survey the ongoing SARS-CoV-2 pandemic, but also vaccination response. The WHO made available a set of well-characterized samples derived from recovered individuals to allow normalization between different quantitative anti-Spike assays to defined Binding Antibody Units (BAU).

METHODS

To assess sero-responses longitudinally, a cohort of ninety-nine SARS-CoV-2 RT-PCR positive subjects was followed up together with forty-five vaccinees without previous infection but with two vaccinations. Sero-responses were evaluated using a total of six different assays: four measuring anti-Spike proteins (converted to BAU), one measuring anti-Nucleocapsid proteins and one SARS-CoV-2 surrogate virus neutralization. Both cohorts were evaluated using the Euroimmun Anti-SARS-CoV-2-ELISA anti-S1 IgG and the Roche Elecsys Anti-SARS-CoV-2 anti-S1 assay.

RESULTS

In SARS-CoV-2-convalesce subjects, the BAU-sero-responses of Euroimmun Anti-SARS-CoV-2-ELISA anti-S1 IgG and Roche Elecsys Anti-SARS-CoV-2 anti-S1 peaked both at 47 (43-51) days, the first assay followed by a slow decay thereafter (> 208 days), while the second assay not presenting any decay within one year. Both assay values in BAUs are only equivalent a few months after infection, elsewhere correction factors up to 10 are necessary. In contrast, in infection-naive vaccinees the assays perform similarly.

CONCLUSION

The results of our study suggest that the establishment of a protective correlate or vaccination booster recommendation based on different assays, although BAU-standardised, is still challenging. At the moment the characteristics of the available assays used are not related, and the BAU-standardisation is unable to correct for that.

Для цитирования: Kroidl Inge, Winter Simon, Rubio-Acero Raquel, Bakuli Abhishek, Geldmacher Christof, Eser Tabea M, Déak Flora, Horn Sacha, Zielke Anna, Ahmed Mohamed I M, Diepers Paulina, Guggenbühl Jessica, Frese Jonathan, Bruger Jan, Puchinger Kerstin, Reich Jakob, Falk Philine, Markgraf Alisa, Fensterseifer Heike, Paunovic Ivana, Thomschke Angelika, Pritsch Michael, Riess Friedrich, Saathoff Elmar, Hoelscher Michael, Olbrich Laura, Castelletti Noemi, Wieser Andreas, KoCo19/ORCHESTRA Study Group. Studying temporal titre evolution of commercial SARS-CoV-2 assays reveals significant shortcomings of using BAU standardization for comparison.. Virology journal. 2023. DOI: 10.1186/s12985-023-02167-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.