Ear and hearing · 2010
Application of the kurtosis statistic to the evaluation of the risk of hearing loss in workers exposed to high-level complex noise.
Сравнительное исследованиеСтатьяПоддержка NIH: внешняя программаНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Zhao Yi-Ming, Qiu Wei, Zeng Lin, Chen Shan-Song, Cheng Xiao-Ru, Davis Robert I, Hamernik Roger P
Аннотация
OBJECTIVE: Develop dose-response relations for two groups of industrial workers exposed to Gaussian or non-Gaussian (complex) types of continuous noises and to investigate what role, if any, the kurtosis statistic can play in the evaluation of industrial noise-induced hearing loss (NIHL).
DESIGN: Audiometric and noise exposure data were acquired on a population (N = 195) of screened workers from a textile manufacturing plant and a metal fabrication facility located in Henan province of China. Thirty-two of the subjects were exposed to non-Gaussian (non-G) noise and 163 were exposed to a Gaussian (G) continuous noise. Each subject was given a general physical and an otologic examination. Hearing threshold levels (0.5-8.0 kHz) were age adjusted (ISI-1999) and the prevalence of NIHL at 3, 4, or 6 kHz was determined. The kurtosis metric, which is sensitive to the peak and temporal characteristics of a noise, was introduced into the calculation of the cumulative noise exposure metric. Using the prevalence of hearing loss and the cumulative noise exposure metric, a dose-response relation for the G and non-G noise-exposed groups was constructed.
RESULTS: An analysis of the noise environments in the two plants showed that the noise exposures in the textile plant were of a Gaussian type with an Leq(A)8hr that varied from 96 to 105 dB whereas the exposures in the metal fabrication facility with an Leq(A)8hr = 95 dB were of a non-G type containing high levels (up to 125 dB peak SPL) of impact noise. The kurtosis statistic was used to quantify the deviation of the non-G noise environment from the Gaussian. The dose-response relation for the non-G noise-exposed subjects showed a higher prevalence of hearing loss for a comparable cumulative noise exposure than did the G noise-exposed subjects. By introducing the kurtosis variable into the temporal component of the cumulative noise exposure calculation, the two dose-response curves could be made to overlap, essentially yielding an equivalent noise-induced effect for the two study groups.
CONCLUSIONS: For the same exposure level, the prevalence of NIHL is greater in workers exposed to non-G noise environments than for workers exposed to G noise. The kurtosis metric may be a reasonable candidate for use in modifying exposure level calculations that are used to estimate the risk of NIHL from any type of noise exposure environment. However, studies involving a large number of workers with well-documented exposures are needed before a relation between a metric such as the kurtosis and the risk of hearing loss can be refined.
DESIGN: Audiometric and noise exposure data were acquired on a population (N = 195) of screened workers from a textile manufacturing plant and a metal fabrication facility located in Henan province of China. Thirty-two of the subjects were exposed to non-Gaussian (non-G) noise and 163 were exposed to a Gaussian (G) continuous noise. Each subject was given a general physical and an otologic examination. Hearing threshold levels (0.5-8.0 kHz) were age adjusted (ISI-1999) and the prevalence of NIHL at 3, 4, or 6 kHz was determined. The kurtosis metric, which is sensitive to the peak and temporal characteristics of a noise, was introduced into the calculation of the cumulative noise exposure metric. Using the prevalence of hearing loss and the cumulative noise exposure metric, a dose-response relation for the G and non-G noise-exposed groups was constructed.
RESULTS: An analysis of the noise environments in the two plants showed that the noise exposures in the textile plant were of a Gaussian type with an Leq(A)8hr that varied from 96 to 105 dB whereas the exposures in the metal fabrication facility with an Leq(A)8hr = 95 dB were of a non-G type containing high levels (up to 125 dB peak SPL) of impact noise. The kurtosis statistic was used to quantify the deviation of the non-G noise environment from the Gaussian. The dose-response relation for the non-G noise-exposed subjects showed a higher prevalence of hearing loss for a comparable cumulative noise exposure than did the G noise-exposed subjects. By introducing the kurtosis variable into the temporal component of the cumulative noise exposure calculation, the two dose-response curves could be made to overlap, essentially yielding an equivalent noise-induced effect for the two study groups.
CONCLUSIONS: For the same exposure level, the prevalence of NIHL is greater in workers exposed to non-G noise environments than for workers exposed to G noise. The kurtosis metric may be a reasonable candidate for use in modifying exposure level calculations that are used to estimate the risk of NIHL from any type of noise exposure environment. However, studies involving a large number of workers with well-documented exposures are needed before a relation between a metric such as the kurtosis and the risk of hearing loss can be refined.