DOI 10.1097/j.jcrs.0000000000001578

Медицинская библиотека · Journal of cataract and refractive surgery · 2025

Accuracy of intraocular lens power calculation in patients with endothelial dystrophy without edema.

Shemer Asaf, Fradkin Maayan, Dubinsky-Pertzov Biana, Reitblat Olga, Simaan Francis, Sella Ruti, Pras Eran, Einan-Lifshitz Adi

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the accuracy of several intraocular lens (IOL) formulas for patients with endothelial dystrophy (ED) without edema treated with cataract surgery alone.

SETTING

1 academic, tertiary referral center.

DESIGN

Comparative retrospective cohort study.

METHODS

The predicted refractive results of patients with ED who underwent cataract surgery were assessed and compared with a matched control group. The accuracy of 5 different IOL formulas, Haigis, Holladay 1, Barrett Universal II (BUII), SRK/T, and Kane, was evaluated and compared between the groups. The SDs of the prediction error (PE) of all formulas were compared.

RESULTS

221 eyes were included in this study. 50 (23%) eyes of patients with ED and 171 (77%) control eyes. There was no significant difference between the 2 groups in clinical and demographical characteristics ( P > .05). The postoperative spherical equivalent was -0.37 diopters (D) in the ED group and -0.30 D in the control group ( P = .8). Overall, both groups had a comparable SD of the PE and absolute PE in all formulas ( P > .05). In the ED group, absolute PE was 0.34 D for Haigis, 0.32 D for Holladay 1, 0.32 D for BUII, 0.38 D for SRK/T, and 0.32 D for Kane formulas. No statistically significant difference between formulas was found.

CONCLUSIONS

The prediction accuracy of IOL power calculation in patients with ED was found comparable both between formulas and in comparison with healthy controls. This suggests that in patients with guttate without edema, the IOL power calculations are as effective and accurate as in healthy eyes.

Для цитирования: Shemer Asaf, Fradkin Maayan, Dubinsky-Pertzov Biana, Reitblat Olga, Simaan Francis, Sella Ruti, Pras Eran, Einan-Lifshitz Adi. Accuracy of intraocular lens power calculation in patients with endothelial dystrophy without edema.. Journal of cataract and refractive surgery. 2025. DOI: 10.1097/j.jcrs.0000000000001578.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.