Comparing an Advanced Monofocal With a Non-diffractive Extended Depth of Focus Intraocular Lens Using a Mini-Monovision Approach.
Аннотация
PURPOSE: To compare interindividual differences in visual performance of an advanced monofocal with a nondiffractive extended depth of focus intraocular lens (IOL) using a mini-monovision approach.
DESIGN
Single-center, randomized, controlled, double-masked study.
METHODS
In total, 48 patients (96 eyes) with bilateral age-related cataract were enrolled. One group received an advanced monofocal IOL RAO200E (RayOne EMV; Rayner) and the other group a non-diffractive extended depth of focus IOL DFT015 (Acrysof IQ Vivity; Alcon) in both eyes. Target refraction for both groups was mini-monovision. After 3 months, monocular and binocular distance corrected and uncorrected distance (CDVA/UDVA), intermediate (DCIVA/UIVA), and near visual acuity (DCNVA/UNVA); contrast sensitivity; binocular defocus curves; halometry; and Quality of Vision questionnaire scores were compared.
RESULTS
Binocular mean CDVA, DCIVA at 66 cm, and DCNVA at 40 cm were -0.10±0.10, 0.15±0.11, and 0.32±0.16 logMAR for the RAO200E and -0.10±0.10, 0.12±0.10, and 0.27±0.16 logMAR for the DFT015, respectively, with no significant difference. A significant difference could be shown for the dominant eye in monocular DCIVA and DCNVA and for the dominant and nondominant eye in monocular UNVA, with 0.28±0.14, 0.48±0.22, 0.46±0.21, and 0.41±0.20 logMAR for the RAO200E and 0.14±0.10 (P = .023), 0.35±0.16 (P = .008), 0.30±0.14 (P = .001), and 0.21±0.10 (P = .003) logMAR for the DFT015, respectively. Significantly smaller halo size in the RAO200E group and significantly better distance-corrected defocus curve at -2.5 (P = .031), -2.0 (P = .03), and -1 diopters (P = .03) of defocus in the DFT015 group could be shown.
CONCLUSIONS
Distance corrected or uncorrected binocular visual acuity for far, intermediate, and near distance between the advanced monofocal IOL RAO200E and the non-diffractive extended depth of focus IOL DFT015, when compared in a mini-monovision setting, showed no significant differences.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.