MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3109/15569527.2010.544277

Медицинская библиотека · Cutaneous and ocular toxicology · 2011

Guinea pig sensitization assays: an experimental comparison of three methods.

Modjtahedi Bobeck S, Fortenbach Christopher R, Marsano Joseph G, Gandhi Aaron M, Staab Robert, Maibach Howard I

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Guinea pig sensitization assays provide a critical tool in toxicological testing. Here, we investigate the relative sensitivities of the Guinea Pig Maximization Test (GPMT), the Open Epicutaneous Test (OET), and the Buehler test on seven common compounds.

METHODS

Seven compounds (formalin, nickel sulfate, 2-benzothiazolethiol, neomycin sulfate, potassium dichromate, ethylenediamine, dihydrochloride, and cinnamyl alcohol) were investigated on 15 guinea pigs per assay. Differences between each assay were investigated individually for each compound in question, and cumulative comparisons were also performed.

RESULTS

Cumulatively, differences in rates of sensitization between the GPMT and OET did not reach statistical significance; however, both tests produced higher sensitization rates than the Buehler test (1% significance level). Comparisons for individual compounds are outlined within the main text.

CONCLUSIONS

Our results indicate a possible role for the OET in the testing of weakly allergenic compounds. Similarly, the Buehler test may hold greatest utility in the examination of strongly allergenic compounds, where high sensitivity is not necessary and limited exposure to subjects is desired. These findings may help guide experimental protocols and considerations.

Для цитирования: Modjtahedi Bobeck S, Fortenbach Christopher R, Marsano Joseph G, Gandhi Aaron M, Staab Robert, Maibach Howard I. Guinea pig sensitization assays: an experimental comparison of three methods.. Cutaneous and ocular toxicology. 2011. DOI: 10.3109/15569527.2010.544277.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.