Oral radiology · 2026

Comparison of supine and prone positions for dental MRI with a microscopy coil: image quality and patient burden in healthy volunteers.

СтатьяСравнительное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Zaike Toshiyuki, Kotaki Shinya, Nakama Hitomi, Ariji Yoshiko, Saito Shigeyoshi

Аннотация

OBJECTIVES: This study aimed to evaluate the clinical feasibility of dental magnetic resonance imaging (MRI) using a microscopy coil by comparing imaging positions in healthy volunteers.

METHODS: Twenty-six healthy volunteers underwent dental MRI in supine and prone positions using a 47 mm microscopy coil on a 3.0T system. T1-weighted (T1W), T2-weighted (T2W), and proton density-weighted (PDW) sequences were acquired. Participant-reported burden was assessed using a 10-point scale. Image quality was evaluated using a 4-point scale for sharpness, artifact, perceived signal-to-noise ratio (SNR), and overall quality. SNR and contrast-to-noise ratio (CNR) were calculated from 1 mm2 regions of interest in dental pulp, inferior alveolar neurovascular bundle, and bone marrow. Statistical analyses included the Wilcoxon signed-rank test, Fisher's exact test, and paired t-test.

RESULTS: Participant-reported burden was lower in the supine position (1.7 ± 1.1) than in the prone (4.7 ± 2.1). Visual assessments demonstrated superior image quality in supine across all sequences. The proportion of non-diagnostic images was higher in the prone position: T1W (50% vs. 19%), T2W (46% vs. 4%), and PDW (38% vs. 8%). SNR and CNR showed no differences between positions. Image quality degraded with prolonged examination time regardless of position.

CONCLUSIONS: The supine position demonstrated lower subjective burden, better visual image quality, and a lower rate of non-diagnostic images compared with the prone position. Image quality was optimal when MRI was performed early in the examination sequence. These findings suggest that the supine position would be more appropriate imaging position for dental MRI using a microscopy coil.