MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/rli.0000000000001035

Медицинская библиотека · Investigative radiology · 2023

Measurement of Abdominal Aortic Aneurysm Strain Using MR Deformable Image Registration: Accuracy and Relationship to Recent Aneurysm Progression.

Dong Huiming, Leach Joseph R, Kao Evan, Zhou Ang, Chitiboi Teodora, Zhu Chengcheng, Ballweber Megan, Jiang Fei, Lee Yoo Jin, Iannuzzi James, Gasper Warren, Saloner David, Hope Michael D, Mitsouras Dimitrios

СтатьяПоддержка исследования: вне правительства СШАПоддержка NIH: внешняя программаПоддержка правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Management of asymptomatic abdominal aortic aneurysm (AAA) based on maximum aneurysm diameter and growth rate fails to preempt many ruptures. Assessment of aortic wall biomechanical properties may improve assessment of progression and rupture risk. This study aimed to assess the accuracy of AAA wall strain measured by cine magnetic resonance imaging (MRI) deformable image registration (MR strain) and investigate its relationship with recent AAA progression.

METHODS

The MR strain accuracy was evaluated in silico against ground truth strain in 54 synthetic MRIs generated from a finite element model simulation of an AAA patient's abdomen for different aortic pulse pressures, tissue motions, signal intensity variations, and image noise. Evaluation included bias with 95% confidence interval (CI) and correlation analysis. Association of MR strain with AAA growth rate was assessed in 25 consecutive patients with >6 months of prior surveillance, for whom cine balanced steady-state free-precession imaging was acquired at the level of the AAA as well as the proximal, normal-caliber aorta. Univariate and multivariate regressions were used to associate growth rate with clinical variables, maximum AAA diameter (D max ), and peak circumferential MR strain through the cardiac cycle. The MR strain interoperator variability was assessed using bias with 95% CI, intraclass correlation coefficient, and coefficient of variation.

RESULTS

In silico experiments revealed an MR strain bias of 0.48% ± 0.42% and a slope of correlation to ground truth strain of 0.963. In vivo, AAA MR strain (1.2% ± 0.6%) was highly reproducible (bias ± 95% CI, 0.03% ± 0.31%; intraclass correlation coefficient, 97.8%; coefficient of variation, 7.14%) and was lower than in the nonaneurysmal aorta (2.4% ± 1.7%). D max ( β = 0.087) and MR strain ( β = -1.563) were both associated with AAA growth rate. The MR strain remained an independent factor associated with growth rate ( β = -0.904) after controlling for D max .

CONCLUSIONS

Deformable image registration analysis can accurately measure the circumferential strain of the AAA wall from standard cine MRI and may offer patient-specific insight regarding AAA progression.

Для цитирования: Dong Huiming, Leach Joseph R, Kao Evan, Zhou Ang, Chitiboi Teodora, Zhu Chengcheng, Ballweber Megan, Jiang Fei, Lee Yoo Jin, Iannuzzi James, Gasper Warren, Saloner David, Hope Michael D, Mitsouras Dimitrios. Measurement of Abdominal Aortic Aneurysm Strain Using MR Deformable Image Registration: Accuracy and Relationship to Recent Aneurysm Progression.. Investigative radiology. 2023. DOI: 10.1097/rli.0000000000001035.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.