MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/bioengineering10080882

Медицинская библиотека · Bioengineering (Basel, Switzerland) · 2023

Evidence in Clinical Studies for the Role of Wall Thickness in Ascending Thoracic Aortic Aneurysms: A Scoping Review.

Debeij Gijs P, Parikh Shaiv, Delhaas Tammo, Bidar Elham, Reesink Koen D

СтатьяScoping ReviewПеревод пока не подготовлен

Аннотация

BACKGROUND

Ascending thoracic aortic aneurysm is a chronic degenerative pathology characterized by dilatation of this segment of the aorta. Clinical guidelines use aortic diameter and growth rate as predictors of rupture and dissection. However, these guidelines neglect the effects of tissue remodeling, which may affect wall thickness. The present study aims to systematically review observational studies to examine to what extent wall thickness is considered and measured in clinical practice.

METHODS

Using PubMed and Web of Science, studies were identified with data on ascending aortic wall thickness, morphology, aortic diameter, and measurement techniques.

RESULTS

15 included studies report several methods by which wall thickness is measured. No association was observed between wall thickness and aortic diameter across included studies. Wall thickness values appear not materially different between aneurysmatic aortas and non-aneurysmal aortas.

CONCLUSIONS

The effects on and consequences of wall thickness changes during ATAA formation are ill-defined. Wall thickness values for aneurysmatic aortas can be similar to aortas with normal diameters. Given the existing notion that wall thickness is a determinant of mechanical stress homeostasis, our review exposes a clear need for consistent as well as clinically applicable methods and studies to quantify wall thickness in ascending aortic aneurysm research.

Для цитирования: Debeij Gijs P, Parikh Shaiv, Delhaas Tammo, Bidar Elham, Reesink Koen D. Evidence in Clinical Studies for the Role of Wall Thickness in Ascending Thoracic Aortic Aneurysms: A Scoping Review.. Bioengineering (Basel, Switzerland). 2023. DOI: 10.3390/bioengineering10080882.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.