MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Rinsho byori. The Japanese journal of clinical pathology · 2009

[Cross-mixing test to detect lupus anticoagulant for diagnosis of antiphospholipid syndrome].

Ieko Masahiro, Naito Sumiyoshi, Yoshida Mika

Аннотация на английскомСтатьяПеревод пока не подготовлен

Аннотация

The activated partial thromboplastin time (APTT) is generally used to screen for intrinsic coagulation factor deficiency. APTT prolongation suggests a bleeding tendency, although it can also reveal the presence of lupus anticoagulant (LA), which is one of the antiphospholipid antibodies associated with a high risk of thrombosis. Therefore, differential diagnosis in patients with a prolonged APTT is important. Recently, a cross mixing test has been proposed as a useful laboratory examination for differential diagnosis in these patients. When a cross-mixing test utilizes a mixture of patient and normal plasma at various ratios, the APTT value of the control plasma is prolonged by the addition of a small amount (10-20%) of the plasma from a patient with LA, while a prolonged APTT in a patient with an intrinsic coagulation factor deficiency is shortened by the addition of control plasma(50%). We obtained more favorable results for LA detection with a cross mixing test by measuring APTT in 5 different mixtures of control plasma and 0, 10, 20, 50, and 100% concentrations of patient plasma with an LA-sensitive APTT reagent such as PTT-LA. Also, we utilized a 0.2 microm filter unit to remove residual platelets from both patient and control plasma samples, which we recommend as useful. We found that a cross-mixing examination with appropriate samples and reagents contributed to the detection of LA. However, some problems remain regarding the final determination and quantitative measurements of LA.

Для цитирования: Ieko Masahiro, Naito Sumiyoshi, Yoshida Mika. [Cross-mixing test to detect lupus anticoagulant for diagnosis of antiphospholipid syndrome].. Rinsho byori. The Japanese journal of clinical pathology. 2009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.