MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12891-025-09199-2

Медицинская библиотека · BMC musculoskeletal disorders · 2025

Augmentation of full-thickness rotator cuff tears with a bioinductive collagen implant does not reduce retear rates - a propensity matched cohort study.

Rab Peter, Shirinskiy Igor J, Kimmeyer Michael, Macken Arno A, Calamita Andrea G, Colombini Antonio G, Buijze Geert Alexander, Lafosse Thibault

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the clinical and radiographic outcomes after full-thickness RC repair with and without performing augmentation with a bioinductive collagen implant (BCI).

MATERIALS AND

METHODS

Consecutive patients who underwent primary repair of a full-thickness supraspinatus tear between 05/2021 and 11/2023 were retrospectively identified. Patients at elevated risk for retear were defined by biological, radiographic, and intraoperative risk factors. Those who underwent repair with or without concomitant augmentation using a BCI and who had both clinical and radiographic follow-up at 1 year postoperatively were matched in a 1:1 ratio according to age, sex, body mass index, tear size, smoking status, diabetes, and American Society of Anesthesiologists physical status classification. Range of motion (ROM) as well as patient-reported outcome measures (Auto-Constant-Score (CS), American Shoulder and Elbow Surgeons (ASES) Score, Subjective Shoulder Value (SSV), and Visual Analog Scale (VAS) for pain) were recorded. Magnetic resonance imaging performed at 1 year postoperatively was analyzed and the presence of retear was recorded.

RESULTS

In total, 149 patients with a radiographic and clinical follow-up at 1 year postoperatively were identified. Of these, 23 patients with BCI augmentation were matched to 23 patients without placement of BCI (48% female, 59.2 ± 8.4 years at surgery). A retear occurred in 5 patients (21.7%) in the BCI augmentation group and in 3 patients (13.0%) in the control group (p = 0.72). No significant difference was reported regarding the CS (77 [71-83] vs. 76 [63-81], p = 0.5), ASES Score (92 [82-98] vs. 90 [84-95], p = 0.8), SSV (90 [80-100] vs. 90 [88-95], p = 0.9), VAS for pain (p = 0.74), or ROM between the groups.

CONCLUSION

In this retrospective matched cohort of patients at elevated risk for retear, augmentation of full-thickness RC repair with a BCI was not associated with a reduced retear rate. Moreover, no significant differences regarding clinical and functional outcome were found between the two groups.

LEVEL OF EVIDENCE: III - Retrospective case series with a matched control group.

Для цитирования: Rab Peter, Shirinskiy Igor J, Kimmeyer Michael, Macken Arno A, Calamita Andrea G, Colombini Antonio G, Buijze Geert Alexander, Lafosse Thibault. Augmentation of full-thickness rotator cuff tears with a bioinductive collagen implant does not reduce retear rates - a propensity matched cohort study.. BMC musculoskeletal disorders. 2025. DOI: 10.1186/s12891-025-09199-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.