Accuracy of acoustic rhinometry versus computed tomography in the evaluation of nasal cavity in patients with nasal polyposis.

Muñoz-Cano R, Salvador R, Valero A, Berenguer J, Alobid I, Bartra J, Guilemany J M, Mullol J, Picado C

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Acoustic rhinometry (AR) accuracy in the diagnosis and follow-up of nasal polyps is as yet unclear. Our objective was to study its accuracy compared with computed tomography (CT) in patients with nasal polyps.

METHODS

We studied 29 patients diagnosed of nasal polyposis by nasal endoscopy. In all patients sinunasal CT-scan, AR and nasal nitric oxide (NO) were assessed. Nasal volumes between 0 and 5 (V(0-5)) and 5 and 9 (V(5-9)) centimetres from nasal inlet were measured with AR and CT-scan, by using Pearson and intraclass correlation coefficient tests.

RESULTS

All patients (29,79% males, mean age 48.2 yr [range 34-61]) had nasal polyps (score 2-3 on Lildholdt classification, score 0-3). Measurements (right plus left sides) were: AR 8.9 +/- 0.8 cm(3) (V(0-5)) and 15.5 +/- 3.6 cm(3)(V(5-9)); CT 6.5 +/- 0.4 cm(3) (V(0-5)) and 6.3 +/- 0.8 cm(3) (V(5-9)). Pearson correlation was r = 0.67 (p < 0.01) for V(0-5) and r = 0.62 (p < 0.05) for V(5-9). Intraclass correlation coefficient test was 0.51 (V(0-5)) and 0.28 (V(5-9)) for consistency; and 0.43 (V(0-5)) and 0.23 (V(5-9)) for absolute agreement. Low levels of NO (312.3 +/- 43.8 ppb) were found and the correlation between NO levels and volumes (V(0-5) or V(0-9)) measured by AR was not statistically significant.

CONCLUSIONS

Compared to CT-scan, AR measurements accurately reflect the geometry of nasal cavity volumes in patients with nasal polyps, with a better assessment in the anterior part of the nasal cavity.

Для цитирования: Muñoz-Cano R, Salvador R, Valero A, Berenguer J, Alobid I, Bartra J, Guilemany J M, Mullol J, Picado C. Accuracy of acoustic rhinometry versus computed tomography in the evaluation of nasal cavity in patients with nasal polyposis.. Rhinology. 2010. DOI: 10.4193/rhin09.067.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.