Comparison of jet injector and insulin pen in controlling plasma glucose and insulin concentrations in type 2 diabetic patients.

Guo Lixin, Xiao Xinhua, Sun Xue, Qi Cuijuan

СтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

This study is conducted to investigate efficacy of an insulin jet injector and an insulin pen in treatment of type 2 diabetic patients. Sixty patients with type 2 diabetes were treated with rapid-acting insulin (regular insulin) and insulin analog (insulin aspart) using the jet injector and the pen in 4 successive test cycles. Postprandial glucose and insulin concentrations in blood were measured over time. Areas under curves of glucose and the insulin were calculated, and efficacy of 2 injection methods in treatment of the diabetes was compared. Regular insulin and insulin aspart administration by the jet injector showed significant decreases in plasma glucose levels as compared to the pen injection (P < 0.05). Postprandial plasma glucose excursions at the time points of 0.5 to 3 hours were obviously lower in the jet-treated patients than the pen-treated ones (P < 0.05). Postprandial plasma insulin levels were markedly higher in the jet-treated patients than the pen-treated ones (P < 0.05). Area under the glucose curve in the pen-treated patients was significantly increased as compared to the jet-treated ones (P < 0.01). Efficacy of the insulin jet injector in treatment of type 2 diabetic patients is obviously superior to the insulin pen in regulating plasma glucose and insulin levels.

Для цитирования: Guo Lixin, Xiao Xinhua, Sun Xue, Qi Cuijuan. Comparison of jet injector and insulin pen in controlling plasma glucose and insulin concentrations in type 2 diabetic patients.. Medicine. 2017. DOI: 10.1097/md.0000000000005482.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.