DOI 10.1161/strokeaha.111.000527
Accuracy of diffusion-weighted imaging in the diagnosis of stroke in patients with suspected cerebral infarct.
Аннотация
BACKGROUND AND PURPOSE: The accuracy of diffusion-weighted imaging (DWI) for the diagnosis of acute cerebral ischemia among patients with suspected ischemic stroke arriving to an emergency room has not been studied in depth.
METHODS
DWI was performed in 712 patients with acute or subacute focal symptoms that suggested an acute ischemic stroke (AIS), 609 of them with AIS.
RESULTS
DWI demonstrated a sensitivity of 90% and specificity of 97%, a positive likelihood ratio of 31 and a negative likelihood ratio of 0.1 for detecting AIS. The overall accuracy was 95%. Of those patients who demonstrated abnormal DWI studies, 99.5% were AIS patients, and of those patients with normal DWI studies 63% were stroke mimics.
CONCLUSIONS
DWI is accurate in detecting AIS in unselected patients with suspected AIS; a negative study should alert for nonischemic conditions.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.