m+Medelevator.RU
← Поиск публикаций
Clinical & experimental ophthalmology · 2011

Comparison of retinal nerve fibre layer thickness with visual evoked potential and visual field in patients with multiple sclerosis.

Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Alpay Atilla, Guney Tuncer, Unal Aysun, Ugurbas Suat H

Аннотация

BACKGROUND: To evaluate retinal nerve fibre layer thickness and to compare results with visual evoked potentials and visual field in patients with multiple sclerosis.

DESIGN: A prospective, case-control study, university hospital setting.

PARTICIPANTS: Seventy-three eyes of 37 multiple sclerosis patients and 74 eyes of 37 healthy subjects.

METHODS: All patients underwent a complete neurological and ophthalmological examination and peri-papillary retinal nerve fibre layer thickness was evaluated using scanning laser polarimetry (GDx). Furthermore, visual evoked potential and visual field testing were performed.

MAIN OUTCOME MEASURES: The χ(2) test, Student's t-test, Mann-Whitney U-test and Pearson's correlation coefficient analysis of the GDx, visual evoked potential and visual field testing parameters.

RESULTS: GDx measurements showed significantly more retinal nerve fibre layer damage in the patients than in the control groups. Comparison of the GDx parameters between patients with optic neuritis and non-optic neuritis demonstrated a statistically significant difference in symmetry (P = 0.046) and superior/nasal parameters (P = 0.009). A correlation was found between the number, superior and inferior ratio parameters, and P100 amplitude obtained with visual evoked potential in patients with non-optic neuritis. Additionally, there was a correlation between the number, inferior ratio and superior/nasal parameters, and the mean deviation of visual field in the non-optic neuritis group.

CONCLUSIONS: For retinal nerve fibre layer thickness measurements in multiple sclerosis patients, the GDx, along with other techniques, such as visual evoked potential, can be used as a diagnostic and follow-up criterion, particularly in patients without optic neuritis.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты