Glass and antimony electrodes for oesophageal pH monitoring in distressed infants: how different are they?

Vandenplas Yvan, Badriul Hegar, Verghote Marc, Hauser Bruno, Kaufman Leonard

Сравнительное исследованиеОценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Although antimony electrodes are by far the most popular for performing oesophageal pH monitoring, there are few data comparing the accuracy of glass and antimony electrodes. Therefore, we tested the accuracy of both electrodes in the prediction of oesophagitis.

METHOD: pH monitoring using a glass electrode and an antimony electrode was performed in 60 distressed infants, aged between 1 and 6 months. An upper endoscopy with oesophageal biopsies was also performed in all infants.

RESULTS

A reflux index (percentage of the total time with pH < 4.0) greater than 5% was considered to be abnormal and was found in 40/60 patients. Histological oesophagitis was present in 26/60 infants. The reflux index was > 5% with the glass electrode in 18/26 children with histological oesophagitis and with the antimony electrode in 10/26 children with histological oesophagitis. Histology of the oesophagus was normal in 22/40 children with abnormal pH monitoring. With the glass electrode, the mean reflux index in the group with oesophagitis was significantly higher than in the group with normal histology, although there was an important overlap. With the antimony electrode, the mean reflux indices in the groups with and without oesophagitis were not different. Regarding normal/abnormal, there was discordance in 35% of the pH studies. No reflux index could be related to a clinically useful sensitivity and specificity to predict oesophagitis.

CONCLUSION

The reflux index does not accurately predict oesophagitis. Oesophageal pH monitoring and endoscopy provide complementary information.

Для цитирования: Vandenplas Yvan, Badriul Hegar, Verghote Marc, Hauser Bruno, Kaufman Leonard. Glass and antimony electrodes for oesophageal pH monitoring in distressed infants: how different are they?. European journal of gastroenterology & hepatology. 2004. DOI: 10.1097/00042737-200412000-00015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.