DOI 10.1167/iovs.05-1504

Медицинская библиотека · Investigative ophthalmology & visual science · 2006

Tear film osmolarity: determination of a referent for dry eye diagnosis.

Tomlinson Alan, Khanal Santosh, Ramaesh Kanna, Diaper Charles, McFadyen Angus

СтатьяМетаанализПеревод в очереди

Аннотация

PURPOSE: To determine new referents, or cutoff levels for tear film hyperosmolarity in the diagnosis of keratoconjunctivitis sicca (KCS) and to assess their effectiveness in independent patient groups.

METHOD: A meta-analysis was performed on published data for tear osmolarity in samples of normal eyes and various subtypes of dry eye, and pooled estimates of the mean and standard deviations for normal and (all) dry eye subjects were determined. Diagnostic referents were derived from the intercept between the distributions of osmolarity in the two samples and from receiver operator characteristic (ROC) curves. This referent was tested for effectiveness of diagnosis in independent groups with normal and dry eyes.

RESULTS

An osmolarity referent of 315.6 mOsmol/L was derived from the intercept of the distribution curves, and 316 mOsmol/L from the ROC curve. When applied to independent groups of normal and dry eye subjects a value of 316 mOsmol/L was found to yield sensitivity of 59%, specificity of 94%, and an overall predictive accuracy of 89% for the diagnosis of dry eye syndrome.

CONCLUSIONS

Tear hyperosmolarity, defined by a referent of 316 mOsmol/L, was superior in overall accuracy to any other single test for dry eye diagnosis (Lactoplate, Schirmer test, and Rose Bengal staining), even when the other test measures were applied to a diagnosis within the sample groups from which they were derived. For overall accuracy in the diagnosis of dry eye, the osmolarity test was found to be comparable with the results of combined (in parallel or series) tests.

Для цитирования: Tomlinson Alan, Khanal Santosh, Ramaesh Kanna, Diaper Charles, McFadyen Angus. Tear film osmolarity: determination of a referent for dry eye diagnosis.. Investigative ophthalmology & visual science. 2006. DOI: 10.1167/iovs.05-1504.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.