INTRODUCTION

The aim of this study was to assess clinical outcomes and quality of life after PFO closure in patients with previous stroke/TIA of undetermined cause and in patients with other complex PFO-associated clinical conditions.

METHODS

Between July 2009 and December 2019 at our University Cardiology Department, 118 consecutive patients underwent a thorough diagnostic work-up including standardized history taking, clinical evaluation, full neurological examination, screening for thrombophilia, brain magnetic resonance imaging (MRI), ultrasound-Doppler sonography of supra-aortic vessels and 24 h ECG Holter monitoring. Anatomo-morphological evaluation using 2D transthoracic/transesophageal echocardiography (TTE/TEE) color Doppler and functional assessment using contrast TTE (cTTE) in the apical four-chamber view and contrast transcranial Doppler (cTCD) using power M-mode modality were performed to verify the presence, location and amount of right-to-left shunting via PFO or other extracardiac source. Completed questionnaires based on the Quality-of-Life Short Form-36 (QoL SF-36) and Migraine Disability Assessment (MIDAS) were obtained from the patients before PFO closure and after 12 months. Contrast TTE/TEE and cTCD were performed at dismission, 1, 6 and 12 months and yearly thereafter. Brain MRI was performed at 1-year follow-up in 54 patients.

RESULTS

Transcatheter PFO closure was performed in 106 selected symptomatic patients (mean age 41.7 ± 10.7 years, range 16-63, 65% women) with the following conditions: ischemic stroke (n = 23), transient ischemic attack (n = 22), peripheral and coronary embolism (n = 2), MRI lesions without cerebrovascular clinical events (n = 53), platypnea-orthodeoxia (n = 1), decompression sickness (n = 1) and refractory migraine without ischemic cerebral lesions (n = 4). The implanted devices were Occlutech Figulla Flex I/II PFO (n = 99), Occlutech UNI (n = 3), Amplatzer PFO (n = 3) and CeraFlex PFO occluders (n = 1). Procedures were performed under local anesthesia and rotational intracardiac monitoring (Ultra ICE) alone. The devices were correctly implanted in all patients. The mean fluoroscopy time was 15 ± 5 min (range = 10-45 min) and the mean procedural time was 55 ± 20 min (range = 35-90 min). The total occlusion rate at follow-up (mean 50 months, range 3-100) was 98.1%. No recurrent neurological events were observed in the long-term follow-up.

CONCLUSIONS

The data collected in this study demonstrate that percutaneous PFO closure is a safe and effective procedure, showing long-term prevention of recurrent cerebrovascular events, significant reduction in migraine symptoms and substantial improvement in quality of life.

Для цитирования: Evola Salvatore, Camarda Emmanuele Antonio, Triolo Oreste Fabio, Adorno Daniele, D'Agostino Alessandro, Novo Giuseppina, Onorato Eustaquio Maria. Clinical Outcomes and Quality of Life after Patent Foramen Ovale (PFO) Closure in Patients with Stroke/Transient Ischemic Attack of Undetermined Cause and Other PFO-Associated Clinical Conditions: A Single-Center Experience.. Journal of clinical medicine. 2023. DOI: 10.3390/jcm12185788.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.