MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.30755

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2023

Transcatheter aortic valve-in-valve implantation within stentless landing zones: Procedural insights from a single-center experience.

Lang Frederick M, Mihatov Nino, Kriegel Jacob, Nazif Tamim M, Vahl Torsten P, Ng Vivian G, Lebehn Mark, Blusztein David, Cahill Thomas J, Lehenbauer Kyle R, Hahn Rebecca T, Leon Martin, Kodali Susheel K, George Isaac

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Valve-in-valve (VIV) transcatheter aortic valve implantation (TAVI) is a less invasive therapeutic option compared with redo surgical valve replacement for high-risk patients. Relative to procedures within stented surgical valves, VIV-TAVI within stentless valves is associated with a higher complication rate due to challenging underlying anatomy and absence of fluoroscopic landmarks.

AIMS: We share a single-center experience with VIV-TAVI in stentless valves, discussing our procedural insights and associated outcomes.

METHODS

Our institutional database was queried, and 25 patients who had undergone VIV-TAVI within a stentless bioprosthesis, homograft, or valve-sparing aortic root replacement between 2013 and 2022 were found. Outcome endpoints were based on the Valve Academic Research Consortium-3 criteria.

RESULTS

The mean age of the cohort was 69.5 ± 13.6 years. VIV implantation was performed within a homograft in 11 patients, a stentless bioprothesis in 10 patients, and a valve-sparing aortic root replacement in 4 patients. Nineteen (76%) balloon-expandable valves, 5 (20%) self-expanding valves, and one mechanically-expandable (4%) valve were implanted with 100% procedural success, with no instances of significant paravalvular leak, coronary occlusion, or device embolization. There was one (4%) in-hospitality mortality after an emergency procedure; one (4%) patient experienced a transient ischemic attack; and two (8%) patients required permanent pacemaker implantation. The median length of hospital stay was 2 days. After a median follow-up time of 16.5 months, valve function was acceptable in all patients with available data.

CONCLUSION

VIV-TAVI within stentless valves can be safely performed with methodical procedural technique and can provide clinical benefit in patients at high reoperation risk.

Для цитирования: Lang Frederick M, Mihatov Nino, Kriegel Jacob, Nazif Tamim M, Vahl Torsten P, Ng Vivian G, Lebehn Mark, Blusztein David, Cahill Thomas J, Lehenbauer Kyle R, Hahn Rebecca T, Leon Martin, Kodali Susheel K, George Isaac. Transcatheter aortic valve-in-valve implantation within stentless landing zones: Procedural insights from a single-center experience.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2023. DOI: 10.1002/ccd.30755.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.