MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejrad.2010.12.042

Медицинская библиотека · European journal of radiology · 2011

Quantitative bronchial luminal volumetric assessment of pulmonary function loss by thin-section MDCT in pulmonary emphysema patients.

Koyama Hisanobu, Ohno Yoshiharu, Yamazaki Youichi, Onishi Yumiko, Takenaka Daisuke, Yoshikawa Takeshi, Nishio Mizuho, Matsumoto Sumiaki, Murase Kenya, Nishimura Yoshihiro, Sugimura Kazuro

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

To determine the capability of quantitative bronchial luminal volume to assess pulmonary function loss and disease severity in pulmonary emphysema patients.

METHODS

Thirty-seven smokers (mean age, 68.1 years) underwent CT examinations and pulmonary function tests. For the quantitative assessment, luminal voxels of trachea and bronchi were computationally counted and the ratio of the following luminal voxels to all luminal voxels was obtained: (1) the lobe bronchi and the peripheral bronchi (Ratio(lobe)), and (2) the main bronchi and the peripheral bronchi (Ratio(main)). To determine the capability of these assessments to predict pulmonary function loss, these ratios were correlated with pulmonary function tests. To determine the capability for predicting disease severity, these ratios were compared between clinical groups.

RESULTS

These ratios were no significant correlated with vital capacity and forced vital capacity (FVC) (p > 0.05), however significantly correlated with forced expiratory volume in 1s (FEV1) (Ratio(lobe): r = 0.61, p < 0.0001, Ratio(main): r = 0.58, p < 0.0005) and FEV1/FVC (Ratio(lobe): r = 0.36, p < 0.05, Ratio(main): r = 0.33, p < 0.05). The Ratio(lobe) of smokers without COPD was significantly different from those of moderate COPD and severe or very severe COPD (p < 0.05), while that of mild COPD was significantly different from that of severe or very severe COPD (p < 0.01). The Ratio(main) of severe or very severe COPD patients was significantly different from those of other groups (p < 0.05).

CONCLUSIONS

Quantitative bronchial luminal volumes were reflected the airflow limitation parameters and was corresponded to clinical groups in emphysema patients.

Для цитирования: Koyama Hisanobu, Ohno Yoshiharu, Yamazaki Youichi, Onishi Yumiko, Takenaka Daisuke, Yoshikawa Takeshi, Nishio Mizuho, Matsumoto Sumiaki, Murase Kenya, Nishimura Yoshihiro, Sugimura Kazuro. Quantitative bronchial luminal volumetric assessment of pulmonary function loss by thin-section MDCT in pulmonary emphysema patients.. European journal of radiology. 2011. DOI: 10.1016/j.ejrad.2010.12.042.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.