MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2214/ajr.09.3653

Медицинская библиотека · AJR. American journal of roentgenology · 2010

Quantitative assessment of bronchial wall attenuation with thin-section CT: An indicator of airflow limitation in chronic obstructive pulmonary disease.

Yamashiro Tsuneo, Matsuoka Shin, Estépar Raúl San José, Dransfield Mark T, Diaz Alejandro, Reilly John J, Patz Samuel, Murayama Sadayuki, Silverman Edwin K, Hatabu Hiroto, Washko George R

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

The purpose of this study was to evaluate the relation between bronchial wall attenuation on thin-section CT images and airflow limitation in persons with chronic obstructive pulmonary disease.

SUBJECTS AND

METHODS

One hundred fourteen subjects (65 men, 49 women; age range, 56-74 years) enrolled in the National Lung Screening Trial underwent chest CT and prebronchodilation spirometry at a single institution. At CT, mean peak wall attenuation, wall area percentage, and luminal area were measured in the third, fourth, and fifth generations of the right B(1) and B(10) segmental bronchi. Correlations with forced expiratory volume in the first second of expiration (FEV(1)) expressed as percentage of predicted value were evaluated with Spearman's rank correlation test.

RESULTS

The peak wall attenuation of each generation of segmental bronchi correlated significantly with FEV(1) as percentage of predicted value (B(1) third, r = -0.323, p = 0.0005; B(1) fourth, r = -0.406, p < 0.0001; B(1) fifth, r = -0.478, p < 0.0001; B(10) third, r = -0.268, p = 0.004; B(10) fourth, r = -0.476, p < 0.0001; B(10) fifth, r = -0.548, p < 0.0001). The correlation coefficients were higher in peripheral airway generations. Wall area percentage and luminal area had similar significant correlations. In multivariate analysis to predict FEV(1) as percentage of predicted value, the coefficient of determination of the model with the combination of percentage of low-attenuation area (< -950 HU) and peak wall attenuation of the fifth generation of the right B(10) was 0.484; the coefficient of determination with percentage of low-attenuation area and wall area percentage was 0.40.

CONCLUSION

Peak attenuation of the bronchial wall measured at CT correlates significantly with expiratory airflow obstruction in subjects with chronic obstructive pulmonary disease, particularly in the distal airways.

Для цитирования: Yamashiro Tsuneo, Matsuoka Shin, Estépar Raúl San José, Dransfield Mark T, Diaz Alejandro, Reilly John J, Patz Samuel, Murayama Sadayuki, Silverman Edwin K, Hatabu Hiroto, Washko George R. Quantitative assessment of bronchial wall attenuation with thin-section CT: An indicator of airflow limitation in chronic obstructive pulmonary disease.. AJR. American journal of roentgenology. 2010. DOI: 10.2214/ajr.09.3653.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.