MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/15910199251398086

Медицинская библиотека · Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025

A retrospective analysis of stent retriever size in M2 occlusion outcomes.

Miller Samantha, Demiraj Francis, Sy Sebastian, Saie Hamzah, Georgiadis Alexandros, Tekle Wondewossen G, Hassan Ameer E

СтатьяПеревод пока не подготовлен

Аннотация

BackgroundMechanical thrombectomy (MT) is the standard of care in acute ischemic stroke, but the efficacy of differently sized stent retrievers (SRs) for MT in M2 segment middle cerebral artery (MCA) occlusions has not been extensively evaluated. We conducted a retrospective study comparing outcomes of 3, 4, and 6 mm SRs in MT at the M2 segment.MethodsData collected from M2 MCA strokes in a comprehensive stroke center were retrospectively analyzed. Patient outcomes were quantified using National Institutes of Health Stroke Scale (NIHSS) 24 h post-procedure and modified Rankin Scale (mRS) scores at discharge and after 90 days. Successful outcomes were defined as an NIHSS score of <10 and an mRS score of <3. First pass success rate and thrombolysis in cerebral infarction (TICI) scores of 2b or greater were also compared. Analysis was performed using chi-square and Kruskal-Wallis tests.ResultsA total of 139 patients with similar baseline demographics underwent MT with SRs sized 3 mm (n = 23), 4 mm (n = 56), and 6 mm (n = 60). No significant difference between groups was noted in 24-h NIHSS (p = 0.83), mRS at discharge (p = 0.597), mRS score at 90 days (p = 0.251), time from groin to recanalization (p = 0.12), or first pass success (p = 0.058). All three sizes had similar complication rates. However, the rate of successful recanalization (final TICI ≥2b) differed significantly between groups (91.3% for 3 mm, 80.4% for 4 mm, and 95.0% for 6 mm; p = 0.043).ConclusionThis retrospective study showed successful recanalization of isolated M2 occlusions was greatest with 6 mm SR.

Для цитирования: Miller Samantha, Demiraj Francis, Sy Sebastian, Saie Hamzah, Georgiadis Alexandros, Tekle Wondewossen G, Hassan Ameer E. A retrospective analysis of stent retriever size in M2 occlusion outcomes.. Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences. 2025. DOI: 10.1177/15910199251398086.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.