World neurosurgery · 2019
Measurement of Active Motor Threshold Using a Dynamometer During Navigated Transcranial Magnetic Stimulation in a Patient with Postoperative Brain Tumor: Technical Note.
Клинический случайСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Ferreira-Pinto Pedro H C, Nigri Flavio, Caparelli-Daquer Egas M, Dutra do Souto Antonio Aversa, de Miranda Chaves Christiani Márcio
Аннотация
BACKGROUND: Navigated transcranial magnetic stimulation (nTMS) is being used for different purposes in patients with brain tumors. However, the procedure requires a positive electrophysiological response. For patients with negative response in rest conditions, active motor threshold (AMT) may be used. However, sometimes it is difficult to obtain AMT measures owing to inability of the patient to sustain steady muscle contraction. Herein, we describe a simple method by using a hand dynamometer to obtain AMT measures during nTMS session.
CASE DESCRIPTION: A woman aged 68 years underwent total removal of a right frontal lobe oligodendroglioma World Health Organization grade II 15 years ago. Cranial magnetic resonance imaging during follow-up revealed local recurrence. In the postoperative period, she developed left upper limb paresis. A postoperative nTMS session was performed for motor electrophysiological evaluation. However, using the standard technique for AMT measurement, the patient was unable to perform sustained muscle contraction as required. A hand dynamometer was used. It allowed sustained muscle contraction for AMT measurement. A counter force for the index finger flexion, the hand support to stabilize hand joints, and a numerical screen serving for both the examiner and the patient as a feedback parameter may explain the success obtained with this simple device.
CONCLUSIONS: Although more studies are necessary to validate the method, the hand dynamometer should be considered for patients unable to sustain muscle contraction during AMT measurement.
CASE DESCRIPTION: A woman aged 68 years underwent total removal of a right frontal lobe oligodendroglioma World Health Organization grade II 15 years ago. Cranial magnetic resonance imaging during follow-up revealed local recurrence. In the postoperative period, she developed left upper limb paresis. A postoperative nTMS session was performed for motor electrophysiological evaluation. However, using the standard technique for AMT measurement, the patient was unable to perform sustained muscle contraction as required. A hand dynamometer was used. It allowed sustained muscle contraction for AMT measurement. A counter force for the index finger flexion, the hand support to stabilize hand joints, and a numerical screen serving for both the examiner and the patient as a feedback parameter may explain the success obtained with this simple device.
CONCLUSIONS: Although more studies are necessary to validate the method, the hand dynamometer should be considered for patients unable to sustain muscle contraction during AMT measurement.