MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.neuroimage.2016.12.040

Медицинская библиотека · NeuroImage · 2017

The effect of acquisition resolution on orientation decoding from V1 BOLD fMRI at 7T.

Sengupta Ayan, Yakupov Renat, Speck Oliver, Pollmann Stefan, Hanke Michael

СтатьяПоддержка исследования: вне правительства СШАПоддержка правительства СШАПеревод пока не подготовлен

Аннотация

A decade after it was shown that the orientation of visual grating stimuli can be decoded from human visual cortex activity by means of multivariate pattern classification of BOLD fMRI data, numerous studies have investigated which aspects of neuronal activity are reflected in BOLD response patterns and are accessible for decoding. However, it remains inconclusive what the effect of acquisition resolution on BOLD fMRI decoding analyses is. The present study is the first to provide empirical ultra high-field fMRI data recorded at four spatial resolutions (0.8mm, 1.4mm, 2mm, and 3mm isotropic voxel size) on this topic - in order to test hypotheses on the strength and spatial scale of orientation discriminating signals. We present detailed analysis, in line with predictions from previous simulation studies, about how the performance of orientation decoding varies with different acquisition resolutions. Moreover, we also examine different spatial filtering procedures and its effects on orientation decoding. Here we show that higher-resolution scans with subsequent down-sampling or low-pass filtering yield no benefit over scans natively recorded in the corresponding lower resolution regarding decoding accuracy. The orientation-related signal in the BOLD fMRI data is spatially broadband in nature, includes both high spatial frequency components, as well as large-scale biases previously proposed in the literature. Moreover, we found above chance-level contribution from large draining veins to orientation decoding. Acquired raw data were publicly released to facilitate further investigation.

Для цитирования: Sengupta Ayan, Yakupov Renat, Speck Oliver, Pollmann Stefan, Hanke Michael. The effect of acquisition resolution on orientation decoding from V1 BOLD fMRI at 7T.. NeuroImage. 2017. DOI: 10.1016/j.neuroimage.2016.12.040.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.