MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jon.12810

Медицинская библиотека · Journal of neuroimaging : official journal of the American Society of Neuroimaging · 2021

Improved Reliability of Automated ASPECTS Evaluation Using Iterative Model Reconstruction from Head CT Scans.

Löffler Maximilian T, Sollmann Nico, Mönch Sebastian, Friedrich Benjamin, Zimmer Claus, Baum Thomas, Maegerlein Christian, Kirschke Jan S

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND AND PURPOSE: Iterative model reconstruction (IMR) has shown to improve computed tomography (CT) image quality compared to hybrid iterative reconstruction (HIR). Alberta Stroke Program Early CT Score (ASPECTS) assessment in early stroke is particularly dependent on high-image quality. Purpose of this study was to investigate the reliability of ASPECTS assessed by humans and software based on HIR and IMR, respectively.

METHODS

Forty-seven consecutive patients with acute anterior circulation large vessel occlusions (LVOs) and successful endovascular thrombectomy were included. ASPECTS was assessed by three neuroradiologists (one attending, two residents) and by automated software in noncontrast axial CT with HIR (iDose4; 5 mm) and IMR (5 and 0.9 mm). Two expert neuroradiologists determined consensus ASPECTS reading using all available image data including MRI. Agreement between four raters (three humans, one software) and consensus were compared using square-weighted kappa (κ).

RESULTS

Human raters achieved moderate to almost perfect agreement (κ = .557-.845) with consensus reading. The attending showed almost perfect agreement for 5 mm HIR (κHIR  = .845), while residents had mostly substantial agreements without clear trends across reconstructions. Software had substantial to almost perfect agreement with consensus, increasing with IMR 5 and 0.9 mm slice thickness (κHIR  = .751, κIMR  = .777, and κIMR0.9  = .814). Agreements inversely declined for these reconstructions for the attending (κHIR  = .845, κIMR  = .763, and κIMR0.9  = .681).

CONCLUSIONS

Human and software rating showed good reliability of ASPECTS across different CT reconstructions. Human raters performed best with the reconstruction algorithms they had most experience with (HIR for the attending). Automated software benefits from higher resolution with better contrasts in IMR with 0.9 mm slice thickness.

Для цитирования: Löffler Maximilian T, Sollmann Nico, Mönch Sebastian, Friedrich Benjamin, Zimmer Claus, Baum Thomas, Maegerlein Christian, Kirschke Jan S. Improved Reliability of Automated ASPECTS Evaluation Using Iterative Model Reconstruction from Head CT Scans.. Journal of neuroimaging : official journal of the American Society of Neuroimaging. 2021. DOI: 10.1111/jon.12810.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.