Conjunctiva in strabismus surgery - to stitch or to stick? - A randomized clinical trial.
Аннотация
PURPOSE: To evaluate the clinical outcomes with fibrin glue in comparison with vicryl sutures for limbal conjunctival wound closure in strabismus surgery.
METHODS
In this prospective interventional study, patients undergoing horizontal muscle strabismus surgery were randomized into two groups: the vicryl suture group and the fibrin glue group. The limbal conjunctival incisions were closed with 8-0 vicryl in the suture group and with fibrin glue in the other group. The outcomes measured were post-operative conjunctival inflammation and wound apposition, patient comfort with the help of a questionnaire, and conjunctival thickness using anterior segment optical coherence tomography (AS-OCT) for both groups at 6 weeks.
RESULTS
The study included 64 eyes of 64 patients (32 eyes in each group). The fibrin glue group performed better than the vicryl suture group for most of the symptoms like redness, irritation, watering, and foreign body sensation till 2 weeks post-operatively ( P < 0.001), after which both the groups performed similarly. As for clinical signs, no significant difference was noted between the two groups, except for conjunctival hyperemia, which was significantly lesser in the fibrin glue group at 2 weeks post-operatively ( P < 0.001). The conjunctival thickness measured at 6 weeks using AS-OCT revealed that the thickness increased significantly in the suture group compared to that in the glue group ( P < 0.001 medial site, P = 0.004 lateral site).
CONCLUSION
Because of greater patient comfort and reduced inflammation associated with fibrin glue, it may be considered as a procedure of choice for conjunctival wound closure in strabismus surgery in the absence of the cost constraints.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.