MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10792-017-0615-2

Медицинская библиотека · International ophthalmology · 2017

Alterations in contact lens fitting parameters following cross-linking in keratoconus patients of Indian ethnicity.

Singh Kirti, Bhattacharyya Mainak, Arora Ritu, Dangda Sonal, Mutreja Ankush

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Most studies have either excluded patients using contact lens or not taken their effect while analyzing post-collagen cross-linkage (CXL) changes. This study aims to study impact of CXL on lens fit in both quantitative and qualitative manner.

OBJECTIVE

To evaluate changes in CL fit post-CXL and to correlate these changes with alterations in corneal topographic parameters.

STUDY

DESIGN

Prospective intervention study on 20 keratoconic eyes of 14 patients (age > 18 years), with mean follow-up of 6 months.

METHODS

Preoperative evaluation included UCVA, BCVA, corneal topography, AS-OCT and contact lens fit. Patients were evaluated at 2 weeks, 1, 3, 4 and 6 months post-CXL; contact lens trial with standard rigid gas permeable (RGP) lens performed at 3 and 6 months.

MAIN OUTCOME MEASURE: Changes in objective and subjective parameters of lens fit.

RESULTS

Over 6-month follow-up post-CXL, improvement in visual acuity by one Snellen line, both UCVA and BCVA, and decrease in flat/mean/apical K by 0.8 D, 0.8 D and 1.3 D, respectively, resulted in significant improvement in RGPCL fit. Almost 20% increase in near-ideal fit, 100% acceptable fit, 65% improved subjective comfort with 8 h/day increase in duration of comfortable CL wear were observed.

CONCLUSION

Despite no statistically significant change in objective parameters of lens fit, a tendency for flatter lens fit along with contact lens induced further flattening of the ectatic cornea which resulted in marked improvement in both objective and subjective contact lens fit.

Для цитирования: Singh Kirti, Bhattacharyya Mainak, Arora Ritu, Dangda Sonal, Mutreja Ankush. Alterations in contact lens fitting parameters following cross-linking in keratoconus patients of Indian ethnicity.. International ophthalmology. 2017. DOI: 10.1007/s10792-017-0615-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.