DOI 10.1097/ico.0000000000001194

Медицинская библиотека · Cornea · 2017

Validation of an Objective Keratoconus Detection System Implemented in a Scheimpflug Tomographer and Comparison With Other Methods.

Ruiz Hidalgo Irene, Rozema Jos J, Saad Alain, Gatinel Damien, Rodriguez Pablo, Zakaria Nadia, Koppen Carina

Сравнительное исследованиеСтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To validate a recently developed program for automatic and objective keratoconus detection (Keratoconus Assistant [KA]) by applying it to a new population and comparing it with other methods described in the literature.

METHODS

KA uses machine learning and 25 Pentacam-derived parameters to classify eyes into subgroups, such as keratoconus, keratoconus suspect, postrefractive surgery, and normal eyes. To validate this program, it was applied to 131 eyes diagnosed separately by experienced corneal specialists from 2 different centers (Fondation Rothschild, Paris, and Antwerp University Hospital [UZA]). The agreement of the KA classification with 7 other indices from the literature was assessed using interrater reliability and confusion matrices. The agreement of the 2 clinical classifications was also assessed.

RESULTS

For keratoconus, KA agreed in 92.6% of cases with the clinical diagnosis by UZA and in 98.0% of cases with the diagnosis by Rothschild. In keratoconus suspect and forme fruste detection, KA agreed in 65.2% (UZA) and 100% (Rothschild) of cases with the clinical assessments. This corresponds with a moderate agreement with a clinical assessment (κ = 0.594 and κ = 0.563 for Rothschild and UZA, respectively). The agreement with the other classification methods ranged from moderate (κ = 0.432; Score) to low (κ = 0.158; KISA%). Both clinical assessments agreed substantially (κ = 0.759) with each other.

CONCLUSIONS

KA is effective at detecting early keratoconus and agrees with trained clinical judgment. As keratoconus detection depends on the method used, we recommend using multiple methods side by side.

Для цитирования: Ruiz Hidalgo Irene, Rozema Jos J, Saad Alain, Gatinel Damien, Rodriguez Pablo, Zakaria Nadia, Koppen Carina. Validation of an Objective Keratoconus Detection System Implemented in a Scheimpflug Tomographer and Comparison With Other Methods.. Cornea. 2017. DOI: 10.1097/ico.0000000000001194.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.