DOI 10.1097/ico.0000000000000978
Intrastromal Corneal Ring Segment Implantation in 409 Paracentral Keratoconic Eyes.
Аннотация
PURPOSE: To assess the efficacy outcomes of implanting intrastromal corneal ring segments (ICRS) to correct paracentral keratoconus.
METHODS
Four hundred nine eyes with paracentral keratoconus, in which the differences between the axes of refractive cylinder and the corneal flattest meridian and the comatic aberration map were less than 30 degrees, were evaluated before and after the implantation of Ferrara-type ICRS. Snellen uncorrected and best-corrected distance visual acuity, residual refractive errors analyzed with vector analysis, and the root mean square for corneal coma-like aberration for a pupil size of 4.5 mm were recorded before and 6 months after ICRS implantation.
RESULTS
The mean uncorrected distance visual acuity (Snellen decimal scale) rose from 0.19 ± 0.19 before ICRS implantation to 0.42 ± 0.30 after implantation (P < 0.0001). The mean preoperative best-corrected distance visual acuity was 0.69 ± 0.24 and the postoperative value was 0.77 ± 0.23 (P < 0.0001). The safety index was 1.13. The spherical equivalent declined steeply after ICRS implantation (P < 0.0001). Cylinder power decreased by more than 50% in 71% of the eyes. The root mean square for corneal coma-like aberration for a 4.5-mm pupil changed from 1.32 ± 1.01 μm before surgery to 1.06 ± 0.85 μm after surgery (P ≤ 0.001).
CONCLUSIONS
The Ferrara-type ICRS implantation is a safe and effective procedure for treating patients with keratoconus that meets the morphological characteristics of the sample under study.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.