Evaluation of anterior and posterior surfaces of the cornea using a dual Scheimpflug analyzer in keratoconus patients implanted with intrastromal corneal ring segments.

Torquetti Leonardo, Arce Carlos, Merayo-Lloves Jesús, Ferrara Guilherme, Ferrara Paulo, Signorelli Brenno, Signorelli Armando

СтатьяПеревод пока не подготовлен

Аннотация

AIM: To evaluate corneal parameters measured with a dual Scheimpflug analyzer in keratoconus patients implanted with intrastromal corneal ring segments (ICRS).

METHODS

Fifty eyes of 40 keratoconus patients had Ferrara ICRS implantation from November 2010 to April 2014. Uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), refraction, keratometry, asphericity, elevation, pachymetry, root mean square (RMS), spherical aberration and coma were studied. All patients were evaluated using a dual Scheimpflug system.

RESULTS

The mean follow-up time after the procedure was 12.7mo. The mean UCVA improved from 0.82 to 0.31 (P<0.001); the mean BCVA improved from 0.42 to 0.05 (P<0.0001), the mean spherical refraction changed from -3.06±3.80 D to -0.80±2.5 D (P<0.0001) and the mean refraction astigmatism reduced from -4.51±2.08 D to -2.26±1.18 D (P<0.0001). The changes from preoperative to postoperative, in parameters of the anterior and posterior surface of the cornea, were statistically significant except the elevation posterior at the apex of the cornea and posterior asphericity.

CONCLUSION

The implantation of Ferrara ICRS induces changes in both anterior and posterior surfaces of the cornea.

Для цитирования: Torquetti Leonardo, Arce Carlos, Merayo-Lloves Jesús, Ferrara Guilherme, Ferrara Paulo, Signorelli Brenno, Signorelli Armando. Evaluation of anterior and posterior surfaces of the cornea using a dual Scheimpflug analyzer in keratoconus patients implanted with intrastromal corneal ring segments.. International journal of ophthalmology. 2016. DOI: 10.18240/ijo.2016.09.08.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.