Srinivasan Visish M, Srivatsan Aditya, Spiotta Alejandro M, Hendricks Benjamin K, Ducruet Andrew F, Albuquerque Felipe C, Puri Ajit, Amans Matthew R, Hetts Steven W, Cooke Daniel L, Ogilvy Christopher S, Thomas Ajith J, Enriquez-Marulanda Alejandro, Rai Ansaar, Boo SoHyun, Carlson Andrew P, Crowley R Webster, Rangel-Castilla Leonardo, Lanzino Giuseppe, Chen Peng Roc, Diaz Orlando, Bohnstedt Bradley N, O'Connor Kyle P, Burkhardt Jan-Karl, Johnson Jeremiah N, Chen Stephen R, Kan Peter
Аннотация
METHODS: This study was a prospective registry of patients treated with PulseRider at 13 American neurointerventional centers following FDA approval of this device. Data collected included clinical presentation, aneurysm characteristics, treatment details, and perioperative events. Follow-up data included degree of aneurysm occlusion and delayed (> 30 days after the procedure) complications.
RESULTS: A total of 54 aneurysms were treated, with the same number of PulseRider devices, across 13 centers. Fourteen cases were in off-label locations (7 anterior communicating artery, 6 middle cerebral artery, and 1 A1 segment anterior cerebral artery aneurysms). The average dome/neck ratio was 1.2. Technical success was achieved in 52 cases (96.2%). Major complications included the following: 3 procedure-related posterior cerebral artery strokes, a device-related intraoperative aneurysm rupture, and a delayed device thrombosis. Immediately postoperative Raymond-Roy occlusion classification (RROC) class 1 was achieved in 21 cases (40.3%), class 2 in 15 (28.8%), and class 3 in 16 cases (30.7%). Additional devices were used in 3 aneurysms. For those patients with 3- or 6-month angiographic follow-up (28 patients), 18 aneurysms (64.2%) were RROC class 1 and 8 (28.5%) were RROC class 2.
CONCLUSIONS: PulseRider is being used in both on- and off-label cases following FDA approval. The clinical and radiographic outcomes are comparable in real-world experience to the outcomes observed in earlier studies. Further experience is needed with the device to determine its role in the neurointerventionalist's armamentarium, especially with regard to its off-label use.