MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ons/opy342

Медицинская библиотека · Operative neurosurgery (Hagerstown, Md.) · 2019

Technical Aspects and Operative Nuances Using a High-Definition 3-Dimensional Exoscope for Cerebral Bypass Surgery.

Nossek Erez, Schneider Julia R, Kwan Kevin, Kulason Kay O, Du Victor, Chakraborty Shamik, Rahme Ralph, Faltings Lukas, Ellis Jason, Ortiz Rafael, Boockvar John A, Langer David J

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Cerebral bypass operation is a technically challenging operation that requires excellent surgical visibility and efficient ergonomics to minimize complications and maximize successful revascularization. Despite the operative microscope's utilization for the past two generations, there remains a need for continued improvement in operative visualization and surgical ergonomics.

OBJECTIVE

To report the positives and negatives of our initial experience using a novel 4 K high-definition (4K-HD) 3-dimensional (3D) exoscope (EX) for cranial bypass surgery.

METHODS

A retrospective review over 6 mo was performed of all patients who have undergone cerebral bypass surgery at a single institution using the 4K-HD 3D EX. Advantages and disadvantages of the EX and clinical outcome of the patients were assessed.

RESULTS

A total of 5 patients underwent cerebral EC-IC bypass surgery with no EX-related complications and successful revascularization. The lightweight design of the EX allowed for easy instrument maneuverability as well as uncomplicated surgical set up in the operating room. The assistance of the cosurgeon was significantly more efficient compared to that of the operating microscope. The large monitor allowed for an immersive, collaborative, and valuable educational surgical experience.

CONCLUSION

Using the EX for cerebral bypass surgery, with 3D ultra-high-definition optics, enhancements of ergonomics, and improved training, we believe that the 3D 4K-HD EX may represent the next generation of operative scopes in microneurosurgery.

Для цитирования: Nossek Erez, Schneider Julia R, Kwan Kevin, Kulason Kay O, Du Victor, Chakraborty Shamik, Rahme Ralph, Faltings Lukas, Ellis Jason, Ortiz Rafael, Boockvar John A, Langer David J. Technical Aspects and Operative Nuances Using a High-Definition 3-Dimensional Exoscope for Cerebral Bypass Surgery.. Operative neurosurgery (Hagerstown, Md.). 2019. DOI: 10.1093/ons/opy342.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.