MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ijg.0000000000000556

Медицинская библиотека · Journal of glaucoma · 2017

The Effect of Laser Photocoagulation on Intraocular Pressure in Premature Infants With Retinopathy of Prematurity.

Erginturk Acar Damla, Acar Ugur, Tunay Zuhal Ozen, Ozdemir Ozdemir

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the effects of diode laser treatment on intraocular pressure (IOP) of premature infants with retinopathy of prematurity (ROP).

PATIENTS AND

METHODS

The premature infants who underwent retinal laser photocoagulation therapy for ROP, and gestational age-matched, birth weight-matched, and sex-matched premature infants with ROP which recovered spontaneously without any treatment were enrolled into the study. Anterior segment examination and longitudinal IOP and central corneal thickness measurements were performed 5 times as follows: 1 day before the laser treatment (T0), and 24 hours (T1), 1 week (T2), 1 month (T3), and 3 months (T4) after the laser treatment. Premature infants who experienced any complication related to the laser treatment were excluded from the study.

RESULTS

Laser treated 67 premature infants and 70 premature infants in control group met inclusion criteria. Significant linear decreases in IOP and central corneal thickness values were measured throughout the study period for both groups (both, P<0.001). These changes were similar in 2 groups. There was a statistically insignificantly (P=0.999) and transient increase in the mean IOP value in the laser-treated group 24 hours after laser treatment. None of the patients in the laser-treated group experienced a shallow anterior chamber or a remarkable IOP elevation.

CONCLUSIONS

Diode laser treatment for ROP was safe, and did not raise the IOP of premature infants.

Для цитирования: Erginturk Acar Damla, Acar Ugur, Tunay Zuhal Ozen, Ozdemir Ozdemir. The Effect of Laser Photocoagulation on Intraocular Pressure in Premature Infants With Retinopathy of Prematurity.. Journal of glaucoma. 2017. DOI: 10.1097/ijg.0000000000000556.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.