DOI 10.1378/chest.126.1.179

Медицинская библиотека · Chest · 2004

Ultrasonographic evaluation of liver/spleen movements and extubation outcome.

Jiang Jung-Rern, Tsai Tzu-Hsiu, Jerng Jih-Shuin, Yu Chong-Jen, Wu Huey-Dong, Yang Pan-Chyr

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

The diaphragm plays a pivotal role in weaning and successful extubation. We hypothesized that ultrasonographic evaluation of the movements of the diaphragm by measuring liver/spleen displacement during spontaneous breathing trials is a good predictor for extubation outcome.

PATIENTS AND

METHODS

The studied subjects were intubated patients receiving mechanical ventilation who were scheduled to be extubated. The displacement of liver/spleen was measured by ultrasonography before extubation. The patients were classified into a success group (SG) or failure group according to the extubation outcome. The baseline data and organ displacements in these two groups were analyzed. The sensitivity and specificity for the mean organ displacements and weaning parameters to predict successful extubation were calculated.

RESULTS

We included 55 patients, 32 of whom (58%) were in the SG. The baseline data are similar for these two groups, but the mean values of liver and spleen displacements were higher in the SG. Using a cutoff value of 1.1 cm, the sensitivity and specificity to predict successful extubation were 84.4% and 82.6%, respectively, better than traditional weaning parameters in this study.

CONCLUSION

The displacement of the liver/spleen, measured by ultrasonography, is a good predictor for extubation outcome.

Для цитирования: Jiang Jung-Rern, Tsai Tzu-Hsiu, Jerng Jih-Shuin, Yu Chong-Jen, Wu Huey-Dong, Yang Pan-Chyr. Ultrasonographic evaluation of liver/spleen movements and extubation outcome.. Chest. 2004. DOI: 10.1378/chest.126.1.179.

Предметные рубрики MeSH