MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejvs.2004.02.004

Медицинская библиотека · European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery · 2004

Sutureless videoendoscopic thoracic aorta to iliac artery bypass: the easiest approach to occlusive aorto-iliac diseases.

Tozzi P, Corno A F, Marty B, von Segesser L K

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

We designed an animal study to determine the feasibility of videoendoscopic thoracic aorta to iliac artery bypass using a sutureless anastomotic device for proximal anastomosis construction.

METHODS

In 12 pigs the descending thoracic aorta was exposed using the thoracoscopic technique. A 4 mm PTFE thin wall graft was used as conduit. The proximal anastomosis was constructed using a mechanical device for sutureless anastomosis inserted through the camera port incision. The prosthesis was passed through the diaphragm in the retroperitoneal space and the distal anastomosis was done with running suture.

RESULTS

The operation was successfully completed in 11 animals. One animal died due to hemorrage during anastomosis construction. Mean graft flow was 144 ml/min (range 88-167 mmHg). The angiogram showed no graft kinking or stenosis. Total operative time was 58 min (range 47-68 min).

CONCLUSIONS

This approach allows quick and excellent exposure of the entire descending thoracic aorta. The use of the sutureless device to perform the proximal anastomosis dramatically reduces the technical demands of this procedure and could avoid an aortic clamp.

Для цитирования: Tozzi P, Corno A F, Marty B, von Segesser L K. Sutureless videoendoscopic thoracic aorta to iliac artery bypass: the easiest approach to occlusive aorto-iliac diseases.. European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery. 2004. DOI: 10.1016/j.ejvs.2004.02.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.