Hemodynamic Assessment of Patients With and Without Heart Failure Symptoms Supported by a Continuous-Flow Left Ventricular Assist Device.

Asleh Rabea, Hasin Tal, Briasoulis Alexandros, Schettle Sarah D, Borlaug Barry A, Behfar Atta, Pereira Naveen L, Edwards Brooks S, Clavell Alfredo L, Joyce Lyle D, Maltais Simon, Stulak John M, Kushwaha Sudhir S

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To investigate differences in invasive hemodynamic parameters and outcomes in patients with and without heart failure (HF) symptoms after left ventricular assist device (LVAD) implantation.

PATIENTS AND

METHODS

We performed a single-center retrospective analysis of 51 symptomatic patients and 50 patients with resolved HF symptoms who underwent right-sided heart catheterization (RHC) after LVAD implantation from March 1, 2007, through June 30, 2016. Patient characteristics and outcomes including all-cause mortality and right ventricular (RV) failure were compared between groups.

RESULTS

Fifty-one patients had development of HF symptoms after LVAD implantation and underwent RHC a mean ± SD of 243.7±288 days postoperatively. Fifty asymptomatic LVAD recipients underwent routine RHC 278.6±205 days after implantation. Compared with patients who had resolved HF symptoms, symptomatic patients were older, more likely to be male, and more likely to have ischemic cardiomyopathy. Symptomatic patients had higher right atrial pressure (P<.001), mean pulmonary arterial pressure (P<.001), and pulmonary capillary wedge pressure (P<.001). Improvements in right atrial pressure, mean pulmonary arterial pressure, and pulmonary capillary wedge pressure before and after LVAD implantation were less remarkable in symptomatic patients. The frequency of RV dysfunction was significantly higher among symptomatic patients than patients with resolved HF symptoms (P=.001). Symptomatic patients displayed significantly higher risk of all-cause mortality (hazard ratio, 3.0; 95% CI, 1.3-6.5; P=.007) and RV failure (hazard ratio, 6.2; 95% CI, 1.3-29.7; P=.02) independent of other predictors of outcome.

CONCLUSION

Patients with recurrent HF symptoms after LVAD implantation display more profound hemodynamic derangements, greater burden of RV failure, and increased rates of all-cause mortality compared with LVAD recipients with resolved HF symptoms.

Для цитирования: Asleh Rabea, Hasin Tal, Briasoulis Alexandros, Schettle Sarah D, Borlaug Barry A, Behfar Atta, Pereira Naveen L, Edwards Brooks S, Clavell Alfredo L, Joyce Lyle D, Maltais Simon, Stulak John M, Kushwaha Sudhir S. Hemodynamic Assessment of Patients With and Without Heart Failure Symptoms Supported by a Continuous-Flow Left Ventricular Assist Device.. Mayo Clinic proceedings. 2018. DOI: 10.1016/j.mayocp.2018.01.031.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.