MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/09246479261453789

Медицинская библиотека · The International journal of risk & safety in medicine · 2026

Batch-dependent safety signal: Nationwide analysis of suspected adverse events following COVID-19 vaccination in Germany.

Manniche Vibeke, Karásek Vít, Schmeling Max, Gilthorpe Jonathan D, Fürst Tomáš, Hansen Peter Riis

СтатьяПеревод пока не подготовлен

Аннотация

BackgroundPreliminary reports have suggested a batch-dependent safety signal for COVID-19 vaccines. It is important to establish if these findings can be replicated.MethodsWe used publicly available nationwide data from Germany spanning the first 3.5 years of the vaccination campaign to calculate weekly rates of spontaneously reported suspected adverse events (SAEs) per 1000 administered vaccine doses.ResultsSAE rates ranged between 2.2 and 22.8 per 1000 doses and women accounted for 72% of all SAEs. Crucially, SAE rates for Comirnaty (Pfizer-BioNTech), Spikevax (Moderna), and Vaxzevria (AstraZeneca) were very high in the initial phase of vaccination rollout and hereafter declined precipitously. For example, SAE rates in weeks 1-4 of 2021 were 8.2, 50.8, and 620.9 per 1000 doses of Comirnaty, Spikevax, and Vaxzevria, respectively, but fell to 4.4, 11.6, and 7.4 per 1000 doses in weeks 12-16 of 2021.ConclusionsSAE rates in Germany were highly elevated in the initial phase of COVID-19 vaccination rollout and then fell precipitously, a pattern compatible with a batch-dependent safety signal. Furthermore, there was a considerable overrepresentation of women with SAEs. These preliminary results call for more definitive studies of batch-dependent COVID-19 vaccine safety.

Для цитирования: Manniche Vibeke, Karásek Vít, Schmeling Max, Gilthorpe Jonathan D, Fürst Tomáš, Hansen Peter Riis. Batch-dependent safety signal: Nationwide analysis of suspected adverse events following COVID-19 vaccination in Germany.. The International journal of risk & safety in medicine. 2026. DOI: 10.1177/09246479261453789.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.