Significance of the disc damage likelihood scale objectively measured by a non-mydriatic fundus camera in preperimetric glaucoma.

Pahlitzsch Milena, Torun Necip, Erb Carl, Bruenner Jeanette, Maier Anna Karina B, Gonnermann Johannes, Bertelmann Eckart, Klamann Matthias K J

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To assess the correlation between the disc damage likelihood scale (DDLS) objectively measured by a non-mydriatic fundus camera, Heidelberg Retina Tomograph 3, and optic coherence tomography in preperimetric glaucoma.

METHODS

One-hundred-twenty-five patients with preperimetric primary open-angle glaucoma (POAG) and pseudoexfoliation glaucoma (n=30) were included (mean age 58.9±15.9 years). All three devices graded the optic disc topography: Diagnosis 1 was defined as "outside normal limits", while Diagnosis 2 as "borderline or outside normal limits".

RESULTS

For Diagnosis 1, a significant correlation was shown between DDLS and Moorfields regression analysis (P=0.022), and for Diagnosis 2 with glaucoma probability score analysis (P=0.024), in POAG. In pseudoexfoliation glaucoma, DDLS did not correlate significantly with Heidelberg Retina Tomograph 3 and optic coherence tomography. Regarding the area under the curve the highest predictive power was demonstrated by the objective DDLS (0.513-0.824) compared to Burk (0.239-0.343) and Mikelberg (0.093-0.270) coefficients.

CONCLUSIONS

The DDLS showed a significant correlation to the Moorfields regression analysis in preperimetric POAG. The objective DDLS showed the highest predictive power and thus is an additive tool in diagnosing preperimetric glaucoma.

Для цитирования: Pahlitzsch Milena, Torun Necip, Erb Carl, Bruenner Jeanette, Maier Anna Karina B, Gonnermann Johannes, Bertelmann Eckart, Klamann Matthias K J. Significance of the disc damage likelihood scale objectively measured by a non-mydriatic fundus camera in preperimetric glaucoma.. Clinical ophthalmology (Auckland, N.Z.). 2015. DOI: 10.2147/opth.s93213.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.