m+Medelevator.RU
← Поиск публикаций
European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery · 2015

Safety, clinical outcome, and fracture rate of femoropopliteal stenting using a 4F compatible delivery system.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Sarkadi H, Bérczi V, Kollár A, Kiss D, Jakabfi P, Végh E M, Nemes B, Merkely B, Hüttl K, Dósa E

Аннотация

OBJECTIVE: To determine the safety, clinical outcome, and fracture rate of femoropopliteal interventions using 4F stents.

METHODS: Between January 2010 and December 2011, 112 symptomatic patients were treated by stent implantation. Ten patients were lost to follow up; therefore, 102 patients (62 men; mean age 66.4 ± 10.1 years) were retrospectively analyzed. The indication for femoropopliteal revascularization was severe claudication (Rutherford-Becker score = 3) in 63 (62%) patients and chronic critical limb ischemia (Rutherford-Becker score = 4-6) in 39 (38%). Follow up included palpation of peripheral pulses and measurement of ankle brachial index. In patients with suspected in-stent restenosis duplex ultrasonography was performed. In 2013, patients were asked to return for a fluoroscopic examination of the stents.

RESULTS: 114 lesions (Trans-Atlantic InterSociety Consensus-C and D, n = 45) were treated with 119 stents (Astron Pulsar, n = 42; Pulsar-18, n = 77). Lesions were long (≥100 mm) in 49 cases and heavily calcified in 35. Stents were long (≥120 mm) in 46 cases. Ten stents were partially overlapped. The technical and clinical success rates were 100%. Two puncture related complications were noted, neither of which required surgical repair. Eleven patients died (myocardial infarction, n = 4; stroke, n = 2; cancer, n = 5) and nine patients underwent major amputation (above knee, n = 4). The primary patency rate was 83% at 6 months and 80% at 12 months. The primary assisted patency rate was 97% at 6 months and 94% at 12 months. The secondary patency rate was 86% at 6 months and 85% at 12 months. The prevalence of fractures was 26% (type III and IV, 10%) after an average follow up of 25 months.

CONCLUSION: Femoropopliteal stenting using a 4F compatible delivery system can be accomplished with a low complication rate, acceptable fracture rate, and with similar 12 month patency and revascularization rates as their 6F counterparts.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты