MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1155/2015/215951

Медицинская библиотека · Journal of ophthalmology · 2015

Corneal Segmentation Analysis Increases Glaucoma Diagnostic Ability of Optic Nerve Head Examination, Heidelberg Retina Tomograph's Moorfield's Regression Analysis, and Glaucoma Probability Score.

Saenz-Frances F, Jañez L, Berrozpe-Villabona C, Borrego-Sanz L, Morales-Fernández L, Acebal-Montero A, Mendez-Hernandez C D, Martinez-de-la-Casa J M, Santos-Bueso E, Garcia-Sanchez J, Garcia-Feijoo J

СтатьяПеревод пока не подготовлен

Аннотация

Purpose. To study whether a corneal thickness segmentation model, consisting in a central circular zone of 1 mm radius centered at the corneal apex (zone I) and five concentric rings of 1 mm width (moving outwards: zones II to VI), could boost the diagnostic accuracy of Heidelberg Retina Tomograph's (HRT's) MRA and GPS. Material and Methods. Cross-sectional study. 121 healthy volunteers and 125 patients with primary open-angle glaucoma. Six binary multivariate logistic regression models were constructed (MOD-A1, MOD-A2, MOD-B1, MOD-B2, MOD-C1, and MOD-C2). The dependent variable was the presence of glaucoma. In MOD-A1, the predictor was the result (presence of glaucoma) of the analysis of the stereophotography of the optic nerve head (ONH). In MOD-B1 and MOD-C1, the predictor was the result of the MRA and GPS, respectively. In MOD-B2 and MOD-C2, the predictors were the same along with corneal variables: central, overall, and zones I to VI thicknesses. This scheme was reproduced for model MOD-A2 (stereophotography along with corneal variables). Models were compared using the area under the receiver operator characteristic curve (AUC). Results. MOD-A1-AUC: 0.771; MOD-A2-AUC: 0.88; MOD-B1-AUC: 0.736; MOD-B2-AUC: 0.845; MOD-C1-AUC: 0.712; MOD-C2-AUC: 0.838. Conclusion. Corneal thickness variables enhance ONH assessment and HRT's MRA and GPS diagnostic capacity.

Для цитирования: Saenz-Frances F, Jañez L, Berrozpe-Villabona C, Borrego-Sanz L, Morales-Fernández L, Acebal-Montero A, Mendez-Hernandez C D, Martinez-de-la-Casa J M, Santos-Bueso E, Garcia-Sanchez J, Garcia-Feijoo J. Corneal Segmentation Analysis Increases Glaucoma Diagnostic Ability of Optic Nerve Head Examination, Heidelberg Retina Tomograph's Moorfield's Regression Analysis, and Glaucoma Probability Score.. Journal of ophthalmology. 2015. DOI: 10.1155/2015/215951.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.