MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ijg.0000000000000233

Медицинская библиотека · Journal of glaucoma · 2016

Structure-Function Correlation Using Confocal Laser Ophthalmoscope in Primary Open-Angle Glaucoma and Pseudoexfoliative Glaucoma.

Pappas Theofanis, Founti Panayiota, Yin Xiang Jun, Koskosas Archimidis, Anastasopoulos Eleftherios, Salonikiou Angeliki, Kilintzis Vasilios, Antoniadis Antonios, Ziakas Nikolaos, Topouzis Fotis

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To compare Heidelberg Retina Tomograph (HRT) optic disc parameters and structure-function correlation between primary open-angle glaucoma (POAG) and pseudoexfoliative glaucoma (PEXG).

DESIGN

Prospective, observation case series.

PATIENTS AND

METHODS

A total of 54 POAG and 33 PEXG cases, consecutively recruited from a University Glaucoma Service, underwent a comprehensive ophthalmic examination, including HRT optic disc imaging. Glaucoma definition required the presence of both structural and functional damage. One eye per subject was included in the analysis. T test, Mann-Whitney U test, and analysis of covariance were used to compare HRT parameters between POAG and PEXG, adjusting for age, mean deviation (MD) in the visual field, intraocular pressure, and disc area. The correlation between HRT and MD was assessed in each group.

RESULTS

Cup area (P=0.048), height variation contour (P=0.016), and cup/disc area ratio (P=0.023) were higher in POAG, whereas the mean retinal nerve fiber layer thickness (P=0.048), retinal nerve fiber layer cross-section area (P=0.044), and rim area (P=0.048) were lower in POAG, compared with PEXG. The correlation of HRT parameters with MD was significant only in the POAG group.

CONCLUSIONS

At a similar level of functional damage, POAG subjects presented with more pronounced structural damage than PEXG subjects. The correlation between HRT and visual field parameters was more evident in POAG, compared with PEXG.

Для цитирования: Pappas Theofanis, Founti Panayiota, Yin Xiang Jun, Koskosas Archimidis, Anastasopoulos Eleftherios, Salonikiou Angeliki, Kilintzis Vasilios, Antoniadis Antonios, Ziakas Nikolaos, Topouzis Fotis. Structure-Function Correlation Using Confocal Laser Ophthalmoscope in Primary Open-Angle Glaucoma and Pseudoexfoliative Glaucoma.. Journal of glaucoma. 2016. DOI: 10.1097/ijg.0000000000000233.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.