Impact of a Digital Power Line Filter in the 2-Global-Flash Multifocal Electroretinogram of Glaucoma Patients Compared to Controls.

Ledolter Anna A, Todorova Margarita G, Schoetzau Andreas, Palmowski-Wolfe Anja M

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To assess the effect of a 50 Hz power line digital filter on the response to a 2-global-flash multifocal electroretinogram (mfERG) in primary open angle glaucoma (POAG) compared to control.

MATERIALS AND

METHODS

A 2-global-flash mfERG (VERIS™) was recorded (23 control, 34 POAG). Eight recordings were noise contaminated: 4 control, 4 POAG. Response averages from the central 10° and 7 surrounding groups were analyzed with and without a 50 Hz digital filter for the following mfERG response epochs: direct component (15-45 ms), 1st (45-75 ms) and 2nd (75-105 ms) induced components.

RESULTS

A digital 50 Hz filter had little effect on uncontaminated with noise waveforms but, in noisy recordings, changed the waveform dramatically to resemble uncontaminated waveforms. In controls' 50 Hz-filtered uncontaminated with noise mfERGs differed significantly from unfiltered responses in induced components. Uncontaminated with noise recordings from glaucoma patients did not differ with or without the notch filter (p > 0.1 for all three epochs of mfERG). The mfERG response in the central 10°in glaucoma patients differed significantly from controls, whether the notch filter was used or not (p < 0.001).

CONCLUSIONS

A 50 Hz notch filter allows grossly contaminated waveforms to be analyzed in a meaningful manner. With a 50 Hz filter, glaucoma patients still differed significantly from normal.

Для цитирования: Ledolter Anna A, Todorova Margarita G, Schoetzau Andreas, Palmowski-Wolfe Anja M. Impact of a Digital Power Line Filter in the 2-Global-Flash Multifocal Electroretinogram of Glaucoma Patients Compared to Controls.. Current eye research. 2015. DOI: 10.3109/02713683.2014.1002043.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.