MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/den.13911

Медицинская библиотека · Digestive endoscopy : official journal of the Japan Gastroenterological Endoscopy Society · 2021

Use of a novel lumen apposing metallic stent for drainage of the bile duct and gallbladder: Long term outcomes of a prospective international trial.

Teoh Anthony Yuen Bun, Kongkam Pradermchai, Bapaye Amol, Ratanachu Thawee, Reknimitr Rungsun, Lakthakia Sundeep, Chan Shannon Melissa, Gadhikar Harshal P, Korrapati Sravan Kumar, Lee Yun Nah, Medarapalem Jahangeer, Ridtitid Wiriyaporn, Moon Jong Ho

Клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Long-term placement of lumen apposing metal stents (LAMS) with high lumen apposing force may result in adverse events. The aim of the current study was to assess the long-term efficacy and safety of a self-approximating LAMS with lower lumen apposing force for endoscopic ultrasound-guided choledochoduodenostomy (EUS-CDS) and -gallbladder drainage (EUS-GBD).

METHODS

Five Asian institutions participated in this study. Consecutive patients suffering from obstructive jaundice with failed ERCP or acute cholecystitis that were at high risk for cholecystectomy were recruited. We evaluated the technical and clinical success rates, adverse events rates, types of interventions through the stent and the patency profile.

RESULTS

From June 2017 to Oct 2018, a total of 53 patients received EUS-CDS (26) and EUS-GBD (27). The technical and clinical success rates were similar between the two groups (88.5% vs 88.9%, P = 1 and 88.5% vs 88.9%, P = 1 respectively). The differences in 30-day mortality rates [2 (7.7%) vs 2 (7.7%), P = 1] and adverse events [3 (11.5%) vs 3 (11.5%), P = 1] did not reach significance. Regarding long-term outcomes, two patients in each group suffered from adverse events (P = 1). One patient in the EUS-GBD group who was on direct oral anticoagulant suffered from stent induced bleeding.

CONCLUSION

The self-approximating LAMS with lower lumen apposing force was effective and safe with a low risk of buried stent syndrome and bleeding in the longer term. The ClinicalTrials.gov Identifier was NCT03002051.

Для цитирования: Teoh Anthony Yuen Bun, Kongkam Pradermchai, Bapaye Amol, Ratanachu Thawee, Reknimitr Rungsun, Lakthakia Sundeep, Chan Shannon Melissa, Gadhikar Harshal P, Korrapati Sravan Kumar, Lee Yun Nah, Medarapalem Jahangeer, Ridtitid Wiriyaporn, Moon Jong Ho. Use of a novel lumen apposing metallic stent for drainage of the bile duct and gallbladder: Long term outcomes of a prospective international trial.. Digestive endoscopy : official journal of the Japan Gastroenterological Endoscopy Society. 2021. DOI: 10.1111/den.13911.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.