MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/ijo.ijo_2859_23

Медицинская библиотека · Indian journal of ophthalmology · 2024

Clinical outcomes of a modified ophthalmic viscosurgical device-free implantable collamer lens implantation.

Wang Chuqiao, Yu Qi, Zhou Qimin, Li Fang, Zhou Jibo

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To investigate the efficacy and safety of a modified dual-incision ophthalmic viscosurgical device-free (OVD-free) method for implantable collamer lens (ICL) implantation in high myopic eyes.

METHODS

A total of 68 participants were enrolled in this prospective randomized clinical trial, including 33 in the OVD-free group and 35 in the standard group. Operation time and intraocular pressure (IOP) at 2 hours postoperatively were recorded. Visual acuity, refractive power, IOP, corneal endothelium parameters, and anterior segment parameters were assessed at 1 day, 1 week, 1 month, 3 months, and 6 months postoperatively. Postoperative subjective visual quality at 3 months was recorded through a Quality of Vision (QoV) questionnaire.

RESULTS

No significant differences in visual acuity, refractive outcomes, and corneal endothelial parameters were found, while the operation time was significantly shorter in the OVD-free group. Both groups showed a significant increase in IOP at 2 hours after surgery, but the increase in the OVD-free group was significantly smaller than that in the standard group. In addition, the frequency of ring-shaped dysphotopsia in the OVD-free group (15.15%) was significantly lower than that in the standard group (40%), and the severity and annoyance of this symptom were also significantly lower in the OVD-free group.

CONCLUSION

The modified OVD-free ICL implantation is a safe, effective, and predictable method for myopia correction, which could be a better choice for short surgery time, better subjective visual perception, and low occurrence of IOP elevation.

Для цитирования: Wang Chuqiao, Yu Qi, Zhou Qimin, Li Fang, Zhou Jibo. Clinical outcomes of a modified ophthalmic viscosurgical device-free implantable collamer lens implantation.. Indian journal of ophthalmology. 2024. DOI: 10.4103/ijo.ijo_2859_23.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.