MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jneumeth.2017.07.003

Медицинская библиотека · Journal of neuroscience methods · 2017

A general protocol of ultra-high resolution MR angiography to image the cerebro-vasculature in 6 different rats strains at high field.

Pastor Géraldine, Jiménez-González María, Plaza-García Sandra, Beraza Marta, Padro Daniel, Ramos-Cabrer Pedro, Reese Torsten

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Differences in the cerebro-vasculature among strains as well as individual animals might explain variability in animal models and thus, a non-invasive method tailored to image cerebral vessel of interest with high signal to noise ratio is required.

NEW METHOD: Experimentally, we describe a new general protocol of three-dimensional time-of-flight magnetic resonance angiography to visualize non-invasively the cerebral vasculature in 6 different rat strains. Flow compensated angiograms of Sprague Dawley, Wistar Kyoto, Lister Hooded, Long Evans, Fisher 344 and Spontaneous Hypertensive Rat strains were obtained without the use of contrast agents. At 11.7T using a repetition time of 60ms, an isotropic resolution of up to 62μm was achieved; total imaging time was 98min for a 3D data set.

RESULTS

The visualization of the cerebral arteries was improved by removing extra-cranial vessels prior to the calculation of maximum intensity projection to obtain the angiograms. Ultimately, we demonstrate that the newly implemented method is also suitable to obtain angiograms following middle cerebral artery occlusion, despite the presence of intense vasogenic edema 24h after reperfusion.

COMPARISON WITH EXISTING

METHODS

The careful selection of the excitation profile and repetition time at a higher static magnetic field allowed an increase in spatial resolution to reliably detect of the hypothalamic artery, the anterior choroidal artery as well as arterial branches of the peri-amygdoidal complex and the optical nerve in six different rat strains.

CONCLUSIONS

MR angiography without contrast agent can be utilized to study cerebro-vascular abnormalities in various animal models.

Для цитирования: Pastor Géraldine, Jiménez-González María, Plaza-García Sandra, Beraza Marta, Padro Daniel, Ramos-Cabrer Pedro, Reese Torsten. A general protocol of ultra-high resolution MR angiography to image the cerebro-vasculature in 6 different rats strains at high field.. Journal of neuroscience methods. 2017. DOI: 10.1016/j.jneumeth.2017.07.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.