Corneal Biomechanical Characteristics in Myopes and Emmetropes Measured by Corvis ST: A Meta-Analysis.

Liu Min-Xin, Zhu Ke-Yao, Li Dan-Lin, Dong Xing-Xuan, Liang Gang, Grzybowski Andrzej, Pan Chen-Wei

СтатьяМетаанализСистематический обзорПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To comprehensively identify the corneal biomechanical differences measured by Corvis ST between different degrees of myopia and emmetropia.

DESIGN

Systematic review and meta-analysis.

METHODS

Electronic databases, including PubMed, Embase, and Web of Science, were systematically searched for studies comparing the corneal biomechanics among various degrees of myopes and emmetropes using Corvis ST. The weighted mean differences and 95% confidence intervals were calculated. Meta-analysis was performed in high and nonhigh myopes and in myopes and emmetropes, respectively.

RESULTS

Eleven studies were included in this study. The meta-analysis among myopes and emmetropes included 1947 myopes and 621 emmetropes, and 443 high myopes and 449 nonhigh myopes were included in the meta-analysis among high and nonhigh myopia. Myopes showed the cornea with significantly longer time at the first applanation (A1t) and lower length at the second applanation (A2L) than emmetropes. High myopes showed significantly greater A1t, velocity at the second applanation (A2v), deformation amplitude at the highest concavity (HC-DA), and peak distance at the highest concavity (HC-PD) and decreased time at the second applanation (A2t) and radius of the highest concavity (HC-R).

CONCLUSIONS

Corneal biomechanics is different in myopia, especially in high myopia. Compared with nonhigh myopes, the corneas of high myopes deformed slower during the first applanation, faster during the second applanation, and showed greater deformation amplitude, indicating greater elasticity and viscidity.

Для цитирования: Liu Min-Xin, Zhu Ke-Yao, Li Dan-Lin, Dong Xing-Xuan, Liang Gang, Grzybowski Andrzej, Pan Chen-Wei. Corneal Biomechanical Characteristics in Myopes and Emmetropes Measured by Corvis ST: A Meta-Analysis.. American journal of ophthalmology. 2024. DOI: 10.1016/j.ajo.2024.03.024.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.